Operating Instructions and Installation Instructions

24
AQUOS - IBIS - IDRON
EN
PRODUCTION (AQUOS 22 H2O / IBIS 22 H2O / IDRON 22 H2O)
Fig. 19 - Plumbing connection
LEGEND
A1 3/4”M heating water delivery
A2 3/4”M heating water return 3/4”M
C 3 bar 1/2” M safety valve
E 1/2”F system emptying
B1 Domestic hot water delivery
B2 Domestic hot water return
8.4 CONNECTION DIAGRAM FOR HYDRO STOVE (IBIS 11 / IDRON 11)
Fig. 20 - Plumbing connection
LEGEND
A1 3/4”M heating water delivery
A2 3/4”M heating water return 3/4”M
C 3 bar 1/2” M safety valve
E 3/4”M system draining and emptying
8.5 SYSTEM CONNECTIONS
Make the connections to the corresponding ttings shown in the diagram on the previous page. Make sure the
pipes are not placed under tension or undersized.