ATTENTION:
The frequency with which the smoke exhaust must be cleaned depends on the use of the
stove and the type of installation.
We recommend contacting an authorised service centre for end-of-season maintenance
and cleaning as the abovementioned operations will be performed together with a general
inspection of the components.
15.14 END-OF-SEASON SHUTDOWN
At the end of each season, before switching the product off, it is recommended to remove all the pellets from
the hopper with a vacuum cleaner that has a long pipe.
The appliance must be disconnected from the mains when it is not used. It is recommended to remove the
power cable for additional safety, especially in the presence of children.
The service fuse may have to be replaced if the control panel display does not go on when the product is next
switched on by pressing the main switch on its side.
There is a fuse compartment on the side of the product, under the power socket. After having disconnected the
plug from the socket, use a screwdriver to open the cover of the fuse compartment and if necessary, replace
them (3.15 A delayed).
Fig. 44 - Fuse compartment