PROBLEMS/CAUSES/SOLUTIONS
16.1 CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualied personnel
whose technical expertise includes combustion and electricity.
It is recommended to perform this routine maintenance annually (with a scheduled service contract), which
focuses on a visual and functional verication of the internal components. The following is a summary of the
necessary checks and/or maintenance for the product to work correctly.
PARTS/INTERVAL EVERY DAY EVERY WEEK 15 DAYS 60-90 DAYS
EVERY
SEASON
Clean the brazier * X
Clean the ash collection
compartment with a vacuum
cleaner *
X
Clean the ash pan X
Clean the glass X
Clean the turbulators X
Clean the lower ash pan X
Clean the “T” exhaust ttings
(outside the stove)
X
Clean the exchangers and remove
ash and incrustations
X
Clean the smoke tting X
Circulation pump inspection X
Hydraulic leaks inspection X
Door gasket inspection X
Start-up spark plug inspection X
* WITH POOR QUALITY PELLETS CLEANING FREQUENCY MUST BE INCREASED.
ATTENTION:
All repairs must only be carried out by a specialised technician, with the product switched
off and the plug disconnected.
If the product is NOT used as described in this instruction manual, the manufacturer declines
all liability for any damage caused to persons and property.
ANOMALY POSSIBLE CAUSES SOLUTIONS
Pellets are not being fed into the
combustion chamber.
The pellet hopper is empty Fill the hopper with pellets.
Sawdust has blocked the feed screw
Empty the hopper and remove the
sawdust from the feed screw by hand.
Faulty gear motor Replace the gear motor.
Faulty electronic board Replace the circuit board.