User manual

12
LEAK TESTING VALUES,
HOSE AND REGULATOR
1. Turn all grill control knobs to OFF
2. Be sure regulator is tightly connected to LP tank.
3. Completely open LP tank valve by turning hand wheel
counter-clockwise. If you hear a sound, turn gas off
immediately. It could mean there is a major leak. Correct before proceeding.
4. Brush soapy solution onto areas circled above.
5. If “rowing” bubbles appear, there is a leak. Close LP tank valve immediately and retighten
connections.
IF LEAKS CANNOT BE STOPPED, DO NOT TRY TO REPAIR.
Call for replacement parts or order new parts.
6. Always close LP tank valve after performing leak test by turning head wheel closkwise.
7. The pressure regulator and hose assembly supplied with this appliance must be used. Replacement
pressure regulator and hose assemblies must be specified by the appliance manufacture.
WARNING
! !
CAUTION
! !
DANGER
! !
For safe use of your grill and to avoid serious injury:
DO NOT let children operate or play near grill.
DO NOT block holes in bottom or back of grill.
Check burner flames regularly.
Use grill in well-ventilated space.
NEVER use in enclosed spaces such as carport, garage, porch,
covered patio, or under an overhead structure of any kind.
DO NOT use charcoal or ceramic briquets in a gas grill (unless briquets are supplied with your grill.)