OWNER’S GUIDE REGISTER POWERFUL PERFORMANCE FOR ANY ROOM For how-to videos or more information, please visit: http://cadetheat.com/install/register ESPAÑOL ver la guía del propietario en cadetheat.com/espanol/register cadetheat.com 855.CADET.
IMPORTANT INSTRUCTIONS ® When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before 7. Do not insert or allow foreign objects to enter any ventilation installing or using this heater. or exhaust opening as this may 2. This heater is hot when in use. cause an electric shock or fire, or To avoid burns, do not let bare damage the heater. skin touch hot surfaces.
INSTALLATION INSTRUCTIONS 1. All electrical work and materials must comply with the National Electric Code (NEC), the Occupational Safety and Health Act (OSHA), and all state and local codes. 2. Use copper conductors only. 3. DO NOT install the heater directly above bathtub or sink. DO NOT install in shower stall area. Manufacturer recommends a minimum 2 foot (61 cm) side clearance. 4. Heater must be installed in a wall can: Model RM - wall can model RMC 5.
INSTALLATION INSTRUCTIONS TIPS BEFORE YOU BEGIN • Verify power has been turned off before starting any work! • The Register model RM can only be mounted with the element up. It cannot be mounted in the ceiling. For multiple heater wiring, see page 6. • For cleaner performance and longer heater life, install your heater 12 inches from the floor. • All models can be installed to be Americans with Disabilities Act (ADA) compliant. Check your state and local requirements.
INSTALLATION INSTRUCTIONS INSERT THE HEATER ASSEMBLY IN THE WALL CAN STEP 4 Wire connections Your heater has two connection wires and the wall can has a green grounding wire. Your supply wire has two connection wires and a supply ground wire. 1. Connect supply ground wire to green grounding wire in wall can (See Figure 3). 2. Connect one of the supply wires to one of your heater wires with a wire connector (not included): A. for 240 volts, it doesn’t matter which heater wire (Figure 3); B.
INSTALLATION INSTRUCTIONS MULTIPLE HEATERS WITH ONE THERMOSTAT More than one heater can be wired in parallel on the same circuit breaker (be sure to check national and local codes for safety requirements). Additional electrical supply wire and cable clamp connectors are required, and you’ll need to use a wall thermostat. When wiring multiple heaters to one thermostat, the heaters must be in the same room and be spaced a minimum of three feet apart.
OPERATING INSTRUCTIONS 1. The heater must be properly installed before it is used. 2. Do not operate without grill. 3. Do not tamper with the hightemperature safety shutoff. How to operate your heater The room temperature is controlled by a thermostat located either on the wall, or on the heater. Once installation is complete and power has been restored, follow the steps below for your thermostat. If you have a wall or built-in thermostat: 1. Turn the thermostat knob all the way to the right. 2.
TROUBLESHOOTING Symptom Problem Solution 1. Supply connections are loose. 1. Turn off power at main disconnect panel. Inspect and/ or tighten all the wire connectors inside the heater and at any connection points inside junction boxes or at the wall thermostat. 2. Heater has tripped its built-in high-temperature safety shutoff and electricity has stopped flowing to the heater. 2. TO RESET: Turn power off at main disconnect panel. Allow 10 minutes to cool. Make sure heater is not blocked and is clean.