Installation Guide

INSTALLATION INSTRUCTIONS
4
Figure 8aFigure 7a
KNOW YOUR VOLTAGE and CHECK YOUR BREAKER!
All baseboards require three supply wires. For 120 volt baseboard wiring you will have 1 hot, 1
neutral and 1 ground. For 240 volt baseboard wiring you will have 2 hots and 1 ground; no neutral
needed.
STEP 2
Baseboard Wiring
Figure 7b
LEFT SIDE WIRING RIGHT SIDE WIRING
Cut ONLY ONE factory connection and ONLY on the side you will be wiring!
Figure 9
1. Multiple baseboard hook-up can be done with
a wall thermostat. Two sets of electrical supply
wires go through the strain relief connector
of baseboard #1. One set of wires goes to
the wall thermostat and the other set goes to
baseboard #2.
2. There are two supply ground wires. You’ll need
another small piece of copper wire to make
the 3-wire connection with the ground screw in
baseboard #1.
3. For baseboard #1, connect each of the cut
baseboard leads to one of the supply wires
going to the thermostat, and one of the supply
wires going to the other baseboard. They both
must have a 3-wire connection.
4. For baseboard #2, make the connections in
the wiring compartment exactly as shown in
7b or 8b above.
MULTIPLE BASEBOARD WIRING 240V SUPPLY ONLY
If you’re wiring on the left side, CUT ONLY THE
ONE FACTORY CONNECTION AT THE TOP.
If you’re wiring on the right side, CUT ONLY THE
FACTORY CONNECTION ON THIS SIDE.
1. Connect one supply wire to one of the heater
wires that was just cut, it doesn’t matter which
one.
2. Connect remaining supply wire to remaining
heater wire.
3. Screw the wiring compartment cover back on.
4. Turn power back on at the main disconnect
panel.
5. Proceed to OPERATING INSTRUCTIONS.
Figure 8b
CUT ONLY
THIS FACTORY
CONNECTION!
DO NOT CUT
BOTH!
CUT ONLY
THIS FACTORY
CONNECTION!
DO NOT CUT!
DO NOT CUT!
supply wires
note: two sets
of electrical
supply wires
going into this
baseboard
supply wires
If you’re wiring a BUILT-IN model BTF or SBF thermostat for your heater, go to those instructions
now and follow that installation. When complete, proceed to OPERATING INSTRUCTIONS.
new
connection
new
connection
new connection
new connection
If you’re wiring a WALL thermostat for your heater, follow the instructions below and the diagrams
in Figures 7b or 8b, depending on which side you are wiring. Your electrical supply wires should be
routed from the circuit breaker to the wall thermostat, and then to the baseboard.
supply
wires
supply wires
to heater #2:
a black, white
and ground
(inset)
#1#2
If you’re wiring a model 8F2025, go to page 5 now.
to the wall
thermostat: a
black, white
and ground
5. Turn power back on at the main disconnect panel.
6. Proceed to OPERATING INSTRUCTIONS.
DO
NOT
CUT!