Specifications

THERMOSTAT
A thermostat is required. A Cadet wall thermostat is recommended
for optimum performance, or you may prefer the convenience of a
built-in thermostat kit. For instructions on wiring a thermostat, see
the instructions that were included with your thermostat. If you
are installing a wall thermostat, refer to the section later in this
guide titled “Baseboard Wiring With a Wall Thermostatprior to
installing the baseboard.
PLACEMENT
For best results, install the baseboard heater under a window,
along an outside wall, or as close as possible to an outside door.
Follow these instructions for selecting an ideal area of installation:
BEFORE PROCEEDING WITH THE INSTALLATION INSTRUCTIONS, YOU MUST
CONSIDER SEVERAL FACTORS THAT ARE CRITICAL TO INSTALLATION
The seam at the junction of the wall and floor behind the heater
should be caulked to prevent dust from being drawn into the room.
Heater should be set flush against surface of the wall.
Remove any obstructions between the back of the unit and the
surface of the wall.
Baseboard heater may sit directly on any floor surface, including
carpet.
Do not allow carpet to block lower air intake located 1 inch from
the bottom.
Maintain at least 12 inches minimum clearance from objects hanging
above (i.e. drapes).
WIRING
Wire connection is possible from either right or left side of the
baseboard heater. Determine which side of the baseboard you are
making wire connections by locating the supply wires. You must
locate the supply wires before mounting the heater. See section
titled “Baseboard Wiring With a Wall Thermostat” prior to wiring
the baseboard if you are installing a wall thermostat.
VOLTAGE (ALL MODELS)
It is extremely important that you verify the electrical supply wires
are the same voltage as the heater (i.e. 120 volt heater to 120 volt
power supply and 240 volt heater to 240 volt power supply). If replacing
an existing heater check the labels of the old heater and replace
using same voltage. Hooking a 240 volt heater to a 120 volt power
supply will drastically reduce the heater’s output. Hooking a 120 volt
heater to a 240 volt power supply will destroy the heater.
WATTAGE (FOR MODEL 8F2025)
Model 8F2025 is a multi-watt unit configured for either 2500 or 2000
watts. The heater is factory set for 2500 watts, but the instructions
vary depending on your desired wattage and which side you are
wiring. Make sure you follow the directions in the Owner’s Guide
for your specific application. It is best to decide on your desired
wattage prior to installing the baseboard.
ABOUT THE CADET ELECTRIC BASEBOARD: The Cadet Electric Baseboard is designed to provide zonal heat to a room by using convection to
naturally circulate warm air. Safety is Cadet’s first priority. All F-Series electric baseboards feature an oversized high temperature limit switch
with a full length capillary sensor tube that temporarily shuts the heater off when excessive operating temperatures are detected. For effective
and safe operation, and to prolong the life of the heater, read all instructions and safety information, and follow the maintenance instructions
in this Owner’s Guide.
See our How-To Video at http://cadetco.com/installationvideo.php
/34$--$4,0//3425&4,0/3
DO NOT INSTALL ANY BASEBOARD
BELOW AN ELECTRICAL OUTLET
DO NOT INSTALL ANY BASEBOARD VERTICALLY.
MOUNT THE BASEBOARD HORIZONTALLY ONLY
2
B
A
CABLEADO DE MÚLTIPLESCALOS.
SUMINISTRO DE 240V SOLAMENTE
(Consulte la figura 14)
1. Cableado del lado izquierdo: desempalme el conector
debrica A. Cableado del lado derecho: desempalme
el conector de fábrica B.
2. Conecte un alambre de cada calentador a un cable de
suministro.
3. Conecte el alambre restante de cada calentador al otro cable
de suministro.
4. Empalme el cable de conexión a tierra del suministro a ambos
tornillos de puesta a tierra usando los calibres correctos.
Nota: No se proporciona cableado de campo
Cableado de múltiples calos - Opcional
Siga las instrucciones que se indican a continuación si va a cablear más de un calentador en paralelo en el mismo circuito.
Si va a cablear múltiples zócalos a un solo control, se recomienda usar un control por habitación.
B
No desconecte
Cableado
de
campo
TierraTierra
Cableado
de campo
Alambres
del
calentador
Al termostato
mural
A
Lado derecho del
calentador de zócalo
Lado izquierdo
del calentador
de zócalo
LOW
Cableado del calo con un termostato mural Opcional
T
ERMOSTATO MURAL DE UN SOLO POLO
1. Tienda los cables de suministro a la caja de cableado del
termostato (si no están presentes).
2. Conecte un cable de suministro a un alambre del termostato
(marcado comúnmente L1).
3
. Tienda el alambre restante del termostato (comúnmente
marcado T1) al calentador de zócalo.
4. Tienda el cable de suministro y puesta a tierra restante
al calentador de zócalo.
5. Siga las instrucciones de instalación para montar y cablear
el calentador de zócalo.
TERMOSTATO MURAL DE DOS POLOS
1. Tienda los cables de suministro a la caja de cableado del
termostato (si no están presentes).
2. Conecte un cable de suministro a un alambre del termostato
(marcado comúnmente L1).
3. Conecte el cable de suministro restante al otro alambre
del termostato (marcado comúnmente L2).
4. Tienda los alambres restantes del termostato (comúnmente
marcados T1 y T2) al calentador de calo.
5. Tienda el cable de puesta a tierra al calentador de zócalo.
6. Siga las instrucciones de instalación para montar y cablear el
calentador decalo.
C
onsulte el siguiente diagrama de cableado que corresponda a su termostato. Nota: Los diagramas de cableado son sólo de
referencia. Consulte las instrucciones del termostato mural incluidas para su aplicacn específica.
Si desea información sobre el cableado usando un termostato incorporado, consulte las instrucciones de instalación de BTF1,
BTF2 y SBFT2 de Cadet
,*52$
,*52$
,*52$
APARECEN CALOS ESTÁNDAR
OFF
Al suministro
Caja de ca-
bleado del
termostato
Caja de ca-
bleado del
termostato
T
ermostato
d
e un solo polo
T
ermostato
d
e dos polos
L1
T1
L2
T2
L
1
T1
A
l calentador
A
l suministro
Al calentador
B
aJo
apagado
11