Installation Guide

ATTACH HEATER
ASSEMBLY HERE
VERTICAL MOUNT:
MODELS CE(F),
CS(F), and CM
HORIZONTAL MOUNT:
MODELS CS(F), and
CM
UP
UP
HAUT
Vancouver, WA cadetheat.com
*Model CS(F)
may be installed in the ceiling (1500
watts or less). Supply connections for ceiling-insert
installation shall use wires suitable for at least 167
° F
(75 ° C).
SURFACE MOUNT WALL CAN MODEL CCSM
070396B
UP
UP
CE(F):
Vertical
mount
only
CS(F)
& CM:
Vertical or
horizontal
mount
ALL
FIELD WIRING OUTSIDE
THESE LINES
HW:
Hori-
zontal
mount
only
.snoitcurtsni noitallatsni etelpmoc rof ediuG srenwO ledom ruoy eeS
HAUT
HAUT
MODEL
Minimum mounting clearances to:
Dégagements minimums de montage aux
:
Floor
surfaces
Surfaces du
plancher
Adjacent
walls
Murs contigus
Ceiling
Plafond
CE(F)4½"
(11.4 cm) 0" (0 cm) 10" (25.4 cm)
CS(F)4½" (11.4 cm) 0" (0 cm)
10" (25.4
cm)
*
CM 4½" (11.4 cm) 6" (15.2 cm) 10" (25.4 cm)
HW 72" (1.8 m) 6" (15.2 cm) 10" (25.4 cm)
Use copper conductors only
.
N’utilisez que des conducteurs en cuivre
.
*
For ceiling-insert installation, do not install
closer than 6 inches (15.2 cm) to any wall.
*
Si installer dans le plafond, maintenir plus de 6 po
(15.2 cm) d’aucun mu
r.
HAUT
TOUT CÂBLAGE DE TERRAIN HORS DE CES LIGNES
HORIZONTAL MOUNT:
MODEL HW
THIS HOLE IS UNUSED
FOR MODEL HW
ATTACH HEATER
ASSEMBLY HERE
ATTACH GRILL HERE
ATTACH HEATER
ASSEMBLY HERE
ATTACH GRILL HERE
UP
UP
HAUT
Vancouver, WA cadetheat.com
*Model CS(F) may be installed in the ceiling (1500
watts or less). Supply connections for ceiling-insert
installation shall use wires suitable for at least 167 ° F
(75 ° C).
SURFACE MOUNT WALL CAN MODEL CCSM
070396B
UP
UP
CE(F):
Vertical
mount
only
CS(F)
& CM:
Vertical or
horizontal
mount
ALL FIELD WIRING OUTSIDE THESE LINES
HW:
Hori-
zontal
mount
only
.snoitcurtsni noitallatsni etelpmoc rof ediuG srenwO ledom ruoy eeS
HAUT
HAUT
MODEL
Minimum mounting clearances to:
Dégagements minimums de montage aux:
Floor
surfaces
Surfaces du
plancher
Adjacent
walls
Murs contigus
Ceiling
Plafond
CE(F)4½"
(11.4 cm) 0" (0 cm) 10" (25.4 cm)
CS(F)4½" (11.4 cm) 0" (0 cm)
10" (25.4
cm)
*
CM 4½"
(11.4 cm)
6"
(15.2 cm)
10"
(25.4 cm)
HW 72" (1.8 m) 6" (15.2 cm) 10" (25.4 cm)
Use copper conductors only.
N’utilisez que des conducteurs en cuivre.
*For ceiling-insert installation, do not install
closer than 6 inches (15.2 cm) to any wall.
*Si installer dans le plafond, maintenir plus de 6 po
(15.2 cm) d’aucun mur.
HAUT
TOUT CÂBLAGE DE TERRAIN HORS DE CES LIGNES
cadetheat.com Tel: 855.CADET.US PO Box 1675 Vancouver, WA 98668-1675
SAVE THESE INSTRUCTIONS
CCSM Surface Mount
Wall Can
Installation Guide
Installation Instructions
Important Instructions
Warranty
TOOLS REQUIRED:
• Phillips Screwdriver
• Straight Screwdriver
• Wire Strippers
• Drill and Drill bits
• (4) Wall Fasteners
• Insulated Wire Connectors
• Conduit Connector
• Strain Relief Connector
Use with any Cadet model HW, CE(F), CS(F), or CM heater
Install heater assembly and grill or decorative cover kit according to the installation instructions included in your original product
Owners Guide.
WARNING
When using electrical appliances, basic precautions should always be followed to reduce the risk of re, electric shock, and injury to
persons. If you are uncomfortable working with electrical appliances, unable to follow these guidelines, or do not have the necessary
equipment; consult a licensed electrician. All steps must be followed.
NOTE: Before mounting the surface wall can, please read your original product Owners Guide or go to cadetheat.com for your heater’s
minimum placement clearances.
STEP 3
Install Heater Assembly and Grill
Feed supply wires through a conduit connector (not included),
leaving 14 inches of wire. Remove a knockout in the surface wall
can closest to the supply wires. Install a strain relief connector
(not included) in the surface wall can knockout. Feed supply wires
through the strain relief connector in the surface wall can and
secure them. Connect supply ground wire to grounding screw.
NOTE: All wiring outside of the surface wall can must be protected
by conduit or other approved devices.
STEP 2
Route Supply Wires
STEP 1
Mount the Surface Wall Can
Review the surface wall can label for correct direction (as noted
by the UP arrows) before mounting. In the vertical mounting po-
sition the element of the heater assembly will be at the top. In the
horizontal mounting position the element of the heater assembly
will be to the left.
Mount the surface wall can securely to the wall, using appropriate
wall fasteners (not included). Refer to your original product Own-
ers Guide for minimum heater clearances from oor, adjacent
walls and ceiling.
PROVIDED:
(1) Grounding Screw
(1) Mounting Screw
For more effective and safer operation and to prolong the life of the heater, read the Own-
er’s Guide and follow the maintenance instructions. Failure to properly maintain the heater
will void any warranty and may cause the heater to function improperly. Warranties are non
transferable and apply to original consumer only. Warranty terms are set out below.
LIMITED ONE-YEAR WARRANTY: Cadet will repair or replace any CADET product,
including thermostats, found to be defective within one year after the date of purchase.
These warranties do not apply:
1. Damage occurs to the product through improper installation or incorrect supply voltage;
2. Damage occurs to the product through improper maintenance, misuse, abuse, accident,
or alteration;
3. The product is serviced by anyone other than Cadet;
4. If the date of manufacture of the product cannot be determined;
5. If the product is damaged during shipping through no fault of Cadet.
6. The use of unauthorized accessories or unauthorized components constitutes an
alteration and voids all warranties. Refer to Cadet website or call customer service at 855.
CADET.US for list of authorized accessories and components.
7. CADET’S WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT AS SET OUT
HEREIN. CADET SHALL NOT BE LIABLE FOR DAMAGES SUCH AS PROPERTY
DAMAGE OR FOR CONSEQUENTIAL DAMAGES AND/OR INCIDENTAL EXPENSES
RESULTING FROM BREACH OF THESE WRITTEN WARRANTIES OR ANY EXPRESS
OR IMPLIED WARRANTY.
8. IN THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR CADET PROD-
UCT, THE REPLACEMENT PARTS ARE SUBJECT TO THE SAME WARRANTIES AS
THE PRODUCT. THE INSTALLATION OF REPLACEMENT PARTS DOES NOT MODIFY
OR EXTEND THE UNDERLYING WARRANTIES. REPLACEMENT OR REPAIR OF ANY
CADET PRODUCT OR PART DOES NOT CREATE ANY NEW WARRANTIES.
9. These warranties give you specic legal rights, and you may also have other rights
which vary from state to state. Cadet neither assumes, nor authorizes anyone to assume
for it, any other obligation or liability in connection with its products other than as set out
herein.
If you believe your Cadet product is defective, please contact Cadet Manufacturing Co. at
855.CADET.US, during the warranty period, for instructions on how to have the repair or
replacement processed. Warranty claims made after the warranty period has expired will
be denied. Products returned without authorization will be refused.
Parts and Service
Visit cadetheat.com/parts-service for information on where to obtain parts and service.
Reduce-Reuse-Recycle
This product is made primarily of recyclable materials. You can reduce your
carbon footprint by recycling this product at the end of its useful life. Contact
your local recycling support center for further recycling instructions.
http://cadetheat.com/products/wall-heaters
Information is also available on our website:
©2016 Cadet Printed in USA Rev 02/16 #720063

Summary of content (1 pages)