OWNER’S GUIDE High output fan-forced heater (CST) Fan-forced heater (CS) Thank you for your purchase! Question or problem? Let us solve it with a single phone call, email or online chat! We’ll save you a trip back to the store! Customer Service: Phone: 888-346-7539 (from US or Canada) Email: cs@glendimplexamericas.com Assembled in USA gdaheat.
IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: 1. Read all instructions before install- 6. To disconnect heater, turn control(s) ing or using this heater. to off, and turn off power to heater cir2. This heater is hot when in use. To cuit at main disconnect panel. avoid burns, do not let bare skin touch 7. Do not insert or allow foreign obhot surfaces.
INSTALLATION INSTRUCTIONS ZIRCON ® 1. All electrical work and materials must comply with the National Electric Code (NEC), the Occupational Safety and Health Act (OSHA), and all state and local codes. Canadian installations must comply with Codes Canada and provincial codes. 2. Use copper conductors only. 3. DO NOT install the heater directly above bathtub or sink. DO NOT install in shower stall area.
¾" (1.9 cm) Min. PARED ADYACENTE INSTALLATION INSTRUCTIONS TIPS BEFORE YOU BEGIN • Verify power has been turned off before starting any work! • Model CS can be mounted with the element up, or with the element on the left. For ceiling installation, see page 5. For multiple heater wiring, see page 6. All the fan-forced heaters have a minimum clearance of 10" (25.4 cm) from the ceiling and 4' (1.2 m) from sprinkler heads. • Model CST can only be mounted with the elements up.
INSTALLATION INSTRUCTIONS INSERT THE HEATER ASSEMBLY IN THE WALL CAN STEP 4 Wire connections 1. Your heater has two connection wires on the back. Your supply wire has two connection wires and a supply ground wire. A. Connect supply ground wire to grounding screw in wall can (See Figure 4 or 5). B. Connect one supply wire to one heater wire with a wire connector (not included): For 240 or 208 volts, it doesn’t matter which heater wire. Both supply wires (black and white) are hot.
INSTALLATION INSTRUCTIONS MULTIPLE HEATERS WITH ONE THERMOSTAT (MODEL CS ONLY) More than one heater can be wired in parallel on the same circuit breaker (be sure to check national and local codes for safety requirements). Additional electrical supply wire and cable clamp connectors are required, and you’ll need to use a wall thermostat. When wiring multiple heaters to one thermostat, the heaters must be in the same room and be spaced a minimum of three feet apart.
OPERATING INSTRUCTIONS 1. Make sure all wires are properly connected and installation is complete before you turn on the heater. 2. Do not operate without grill. 3. Do not tamper with the hightemperature safety shutoff. Complete installation After installation, turn your heater to the highest setting and let it run for 30 minutes. Some smoking may occur as the element initially burns off residue from manufacturing.
MAINTAINING YOUR HEATER lean heater at least every 6 months or as required. Do not lubricate motor. C WARNING: Risk of electrical shock, turn off power before removing grill. 1. Turn off power at the main disconnect panel. 2. Wait for the heater to cool. 3. Remove thermostat knob (if any) and grill. 4. Wash grill with hot soapy water and dry. 5. Blow air through the heating element with a hair dryer or shop vacuum on blow cycle. 6. Clean the fan with a vacuum cleaner. 7.