Technical Information Manual Revision n. 2 2 April 2008 Mod. A528 OEM UHF MULTIREGIONAL COMPACT READER NPO: 00101/07:A528X.
Federal Communications Commission (FCC) Notice (Preliminary) This device was tested and found to comply with the limits set forth in Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.
Document type: User's Manual (MUT) Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 INDEX 1. INTRODUCTION ..................................................................................................................................................5 2. MOD. A528 TECHNICAL SPECIFICATIONS .................................................................................................6 2.1. MOD. A528 TECHNICAL SPECIFICATIONS TABLE ........................
Document type: User's Manual (MUT) Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 LIST OF TABLES TABLE 2.1: MOD. A528 TECHNICAL SPECIFICATIONS ...............................................................................................6 TABLE 2: A528 MAIN CONNECTOR PINOUT..............................................................................................................8 TABLE 2.3: A528 MAIN CONNECTOR ELECTRICAL CHARACTERISTICS ..................
Document type: User's Manual (MUT) Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 1. Introduction The A528 is an OEM UHF multiregional compact reader for integration into label printers, label applicators, handheld devices and in general any fixed or mobile short and medium range device requiring UHF tag programming and reading.
Document type: User's Manual (MUT) Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 2. Mod. A528 Technical Specifications 2.1. Mod. A528 Technical Specifications Table Table 2.1: Mod. A528 Technical Specifications 902÷928 MHz (FCC part 15) Frequency band 865.600÷867.
Document type: User's Manual (MUT) 2.2. Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 External connections The location of the connectors is shown in Fig. 2.1.
Document type: User's Manual (MUT) 2.2.1. Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 A528 Main connector pinout Compact reader A528 MAIN external connector is a Molex SMD, 12 poles, 1.27 pitch connector whose pinout is shown in table below.
Document type: User's Manual (MUT) 2.2.2. Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 A528 MAIN connector electrical characteristics Table 2.3: A528 main connector electrical characteristics Pin name +5V /RESET GPIO[0:3] Pin No. 1 Parameter Min. Typ. Max. Unit Supply DC voltage 4.75 5.00 5.25 V 100 mVpp Power supply requirements – Ripple Voltage Power supply requirements - Ripple Frequency 100 Supply DC current 0.23 1.0 A VIL -0.
Document type: User's Manual (MUT) 2.2.3. Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 Power supply connection In the following schematic suggested A528 power supply connection is shown. The use of fuse F1 is recommended since A528 doesn't provide internal current limitation protection. Diode D1 avoid damage to the reader in case of reverse polarity connection. The use of optional LC filter improves reader immunity in presence of noisy power supply.
Document type: User's Manual (MUT) Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 Fig. 2-3: Mod. A528 GPIO connection example 2.2.5. External reset A528 manual reset can be performed by forcing at low level /RESET pin for 1μS at least. /RESET pin is pulled-up by an internal resistor. Fig. 2-4: Mod. A528 external reset NPO: 00101/07:A528X.MUTx/02 Filename: A528_REV02.
Document type: User's Manual (MUT) 2.2.6. Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 UART connection The RXD/TXD pins are used to communicate with the A528 board via UART port. Since A528 RX/TX are TTL level signals, in order to connect it with a PC, a TTL/RS232 translator shall be used (please refer to the diagram below) 4. To establish a link with the device host COM port shall be configured as follows: 1. Baud rate: 115200 2. Parity: None 3.
Document type: User's Manual (MUT) Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 Fig. 2-6: Mod. A528 TST-recovery connection 2.2.8. A528 USB connector pinout A528 USB interface connector is a Molex SMD, 2 poles, 1.27 pitch connector whose pinout is shown in table below. Table 2.
Document type: User's Manual (MUT) 2.2.9. Pin name Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 USB connector pinout electrical characteristics Pin No. Parameter Min. Typ. VIL 1 DDM 0.8 V 2 V VOL 0 0.3 V VOH 2.8 3.3 V 27 VIL 2 Unit VIH Recommended external series resistor DDP Max. Ω 0.8 V VIH 2 VOL 0 0.3 V VOH 2.8 3.3 V Recommended external series resistor V 27 Ω Table 2.
Document type: User's Manual (MUT) Title: Mod. A528 OEM UHF Multiregional compact reader Parameter Min. Revision date: 02/04/2008 Typ. Revision: 2 Max. Unit 10 500 mW 10 27 dBm ±1 dB RF output power Output power vs. power setting accuracy RF port impedance 50 Ω Recommended antenna VSWR 2:1 - Table 2.7: RF port electrical characteristics 2.3. Reader – Tag link profiles A528 reader supports different modulation and return link profiles according to EPC Class1 Gen2 protocol.
Document type: User's Manual (MUT) Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 Intel RFID Tracer and libraries included in the Intel SDK. Using Intel protocol, serial interface has debug purpose only. The default setting of the A528 reader is the Serial/CAEN choice, in order to switch to the INTEL protocol on USB interface you shall follow the steps described below: 1.
Document type: User's Manual (MUT) 2.5.1. Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 A528 USB Recovery/FW upgrade USB upgrade is based on Atmel Smart Arm Microcontroller Boot Assistant (hence forth referred to as “SAM-BA”). The SAM-BA tools is distributed by Atmel via http://www.atmel.com/dyn/products/tools_card.asp?tool_id=3883 (download and install AT91-ISP.exe file). USB upgrade requires the following steps: 1.
Document type: User's Manual (MUT) 2.5.2. Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 A528 RS232 FW upgrade To perform the FW upgrade via RS-232 interface these steps shall be followed: 1. Turn off the reader 2. Connect the reader with the RS232 serial cable to your PC using the adapter board A528ADAT. 3.
Document type: User's Manual (MUT) Title: Mod. A528 OEM UHF Multiregional compact reader Revision date: 02/04/2008 Revision: 2 7. Launch the upgrade tool (AT91SAM7SERIALBOOT.exe) provided into CAEN SDK CD-ROM on your PC. 8. Select the COM port you are using (typically is COM1) with the radio button on the left of the main window and press the connect button. 9. Click the Open button and Browse until you find the .bin firmware upgrade image 10. Press the Download button.