User's Manual

Document type: Title: Revision date: Revision:
User's Manual (MUT) Mod. A528 OEM UHF Multiregional compact reader 02/04/2008 2
2.5.2. A528 RS232 FW upgrade
To perform the FW upgrade via RS-232 interface these steps shall be followed:
1. Turn off the reader
2. Connect the reader with the RS232 serial cable to your PC using the adapter
board A528ADAT.
3. Setup a serial terminal (such hyperterminal available on all windows OS) with the
following settings:
- baud rate: 115200
- data bits: 8
- parity: none
- stop bits: 1
- Flow control: None
4. Turn on the reader.
If A528 is configured to use INTEL protocol a boot message (see
Fig. 2-8 ) will
appear press the space bar within 6 seconds from boot.
Fig. 2-8: Mod. A528 debug shell window
If A528 is configured to use CAEN protocol no boot message will appear: in this
case you shall type quickly and in capital letters the word “CAEN”.
5. After that in both cases a prompt ">" should be displayed. The reader is waiting
for commands to be sent over the serial port.
6. Type "upgrade", press return and disconnect the serial port
NPO: Filename: Number of pages: Page:
00101/07:A528X.MUTx/02 A528_REV02.DOC 19 18