User's Manual

EXAMPLES - CAEN UHF RFID Readers Communication Protocol 31
ReadTagData_EPC_C1G2 Command
Command sent:
0x8001 (Fixed)
0x000E (Message ID)
0x00005358 (Vendor ID = CAEN SpA)
0x0053 (Message Length)
0x0000 (Reserved)
0x0008 (AVP Length)
0x0001 (AVP Type = CommandName)
0x0096 (AVP Value = ReadTagData_EPC_C1G2)
0x0000 (Reserved)
0x000F (AVP Length)
0x00FB (AVP Type = SourceName)
0x536F757263655F3000 (AVP Value)
0x0000 (Reserved)
0x0008 (AVP Length)
0x000F (AVP Type = TagIDLen)
0x000C (AVP Value = 96 bit)
0x0000 (Reserved)
0x0012 (AVP Length)
0x0011 (AVP Type = TagID)
0x300833B2DDD9014035050000
0x0000 (Reserved)
0x0008 (AVP Length)
0x0071 (AVP Type = Memory Bank)
0x0003 (AVP Value = User Memory Bank)
0x0000 (Reserved)
0x0008 (AVP Length)
0x004e (AVP Type = Tag Address)
0x0000 (AVP Value = Address)
0x0000 (Reserved)
0x0008 (AVP Length)
0x0050 (AVP Type = Length)
0x0004 (AVP Value = # of bytes)
Response received:
0x0001 (Fixed)
0x000E (Message ID)
0x00005358 (Vendor ID = CAEN SpA)
0x0024 (Overall Message Length)
0x0000 (Reserved)
0x0008 (AVP Length)
0x0001 (AVP Type = CommandName)
0x0096 (AVP Value = ReadTagData_EPC_C1G2)
0x0000 (Reserved)
0x000A (AVP Length)
0x004d (AVP Type = Tag Value)
0x00000000 (AVP Value = bytes to be read)
0x0000 (Reserved)
0x0008 (AVP Length)
0x0002 (AVP Type = ResultCode)
0x0000 (AVP Value = Success)