CONFIGURATION USING THE WEB INTERFACE - Quattro Technical Information Manual 24
The correspondent values are:
Percentage
Conducted Power
ETSI
(mW)
Conducted Power
FCC
(mW)
5%
70
70
10%
140
140
20%
280
280
40%
560
560
60%
840
840
80%
1120
1000
4
100%
1400
1000
3
Tab. 4.2: Conducted power
Code: alphanumeric characters. The “code” is the name assigned by the user to the custom
program. When the reader is turned on, if the profile is set to custom, among all the programs
loaded by the user, the reader starts the custom program named "code".
Parameters: alphanumeric characters. This string can be used to assign values to the parameters
defined by the user in the custom program (e.g. Q=8; n=6; cycles=20, etc…).
Y
Warning: To save the changes click on the SAVEbutton. Note that all changes made via the
web interface are active only after the reader’s reboot. Click on SYSTEM option in the Web
Interface panel and then click on the “Reboot” button. After reboot, the new settings are active.
INFO
4
The reader with the FCC regulation cannot supply more than 1000 mW to the connector. By analogy with the power expressed in the
ETSI table, the percentage refers to the full scale of 1400mW, but the percentage of 80% and 100% (that exceed 1000mW) are limited
to the maximum of 1000 mW.