Use and Care / Installation Manual
Table Of Contents
10 31-2000814 Rev. 1
Installation
4
CONVERTING TO PROPANE (LP)
GAS OR CONVERTING BACK
TO NATURAL GAS FROM
PROPANE (LP)
Thisrangeleavesthefactorysetforusewithnatural
gas.Ifyouwanttoconverttopropane(LP)gas,the
conversion must be performed by a qualified propane
(LP) gas installer.
The conversion orifices
and instructions can
be found on back of
the range.
Keep these
instructions and all
orifices in case you
wanttoconvertback
to natural gas.
5
GAS SUPPLY
WARNING
FireHazard:Donotuseaflameto
check for gas leaks.
WARNING
ExplosionHazard:Donotexceed
25ft-lbsoftorquewhenmakinggaslineconnections.
Overtightening may damage the pressure regulator
resultinginfireorexplosionhazard.
Gas Pressure Regulator
You must use the gas pressure regulator supplied
withthisrange.Forproperoperationstheinlet
pressuretotheregulatorshouldbeasfollows:
Natural Gas:
Minimumpressure:6”ofWaterColumn
Maximumpressure:13”ofWaterColumn
Propane (LP) Gas:
Minimumpressure:11”ofWaterColumn
Maximumpressure:13”ofWaterColumn
If you are not sure about the inlet pressure contact
local gas supplier.
NOTE:Agasshutoffvalveisshippedwiththisrange
and should be installed at the rear of the range near
thefloorwiththehandle
facingdownward.Thisshut-
off valve is to be used in the
event that service is required.
Toaccesstheshut-offvalve,
remove the toe-kick panel
and reach under the range.
Anoptional1/2”elbowis
provided for connection to
the range gas inlet.
5
GAS SUPPLY (cont.)
Shut off the main gas supply valve before
disconnecting the old range and leave it off until
the new hook-up has been completed. Don’t
forget to relight the pilot on other gas appliances
when you turn the gas back on.
Becausehardpipingrestrictsmovementoftherange,
theuseofaCSAInternational-certifiedflexiblemetal
appliance connector is recommended unless local
codes require a hard-piped connection.
Ifthehardpipingmethodisused,youmustcarefully
alignthepipe;therangecannotbemovedafterthe
connection is made.
Topreventgasleaks,putpipethreadsealanton,or
wrappipethreadtapewithTeflon*around,allmale
(external)pipethreads.
A. Install a manual shut-off valve in the gas line in an
easily accessed location outside of the range. Make
sureeveryoneoperatingtherangeknowswhere
andhowtoshutoffthegassupplytotherange.
B. Installmale1/2”flareunionadaptertothe1/2”
NPT internal thread at inlet of the shut-off valve on
therange.Useabackupwrenchontheshut-off
valve to avoid damage.
C. Installmale1/2”or3/4”flareunionadaptertothe
NPTinternalthreadofthehouseshut-offvalve,
taking care to back-up the shut-off valve to keep it
from turning.
D. Connectflexiblemetalapplianceconnectortothe
adapter on the range. Position range to permit
connection at the house shut-off valve.
E. Whenallconnectionshavebeenmade,makesure
all range controls are in the off position and turn
on the main gas supply valve. Use a liquid leak
detector at all gas connections to check for leaks
in the system.
Whenusingpressuresgreaterthan1/2psigto
pressuretestthegassupplysystemoftheresidence,
disconnect the range and individual shut-off valve
from the gas supply piping. When using pressures
of1/2psigorlesstopressuretestthegassupply
system,simplyisolatetherangefromthegassupply
system by closing the individual shut-off valve.
Whencheckingforproperoperationoftheregulator,
the inlet pressure must be at least 1” greater than the
operating (manifold) pressure as given on rating label
of product.
*Teflon:RegisteredtrademarkofDuPont
Gas Inlet
Oven
Regulator
Cooktop Regulator
Propane