Installation Instructions

31-2000356 Rev.1 5
Standard Installation Preparation
PREPARE THE OPENING
The Advantium 240V can be installed in combination
with other Built-In appliances. Always follow each
product’s Installation Instructions to complete the
installation.
Single Advantium 240V Installation:
Order a 30” wide single oven cabinet or cut the
opening in a wall to the dimensions shown.
30”
23-1/2”
25-1/4”
17-1/2”
Construct
Base
Min. 3/8”
Plywood
Supported
by 2x4
or 2x2
Runners all
Four Sides
36-3/4”
Min.
Always maintain 36-3/4” minimum height from
the floor to the cutout in any single or combined
installation.
Allow the following clearances around the cutout
RQWKHIURQWVXUIDFHRIWKHFDELQHWí´IURPWKH
WRSí´IURPWKHVLGHHGJHVDQGí´IURPWKH
bottom. (Note: these refer to minimum clearances
required for installation and do not reflect actual
product dimensions.)
Oven overlaps will conceal cut edges on all sides of
the opening.
When installed over a single oven or a warming
drawer, allow at least 2” between the two openings.
This separation will provide clearance for bottom
overlap of the Advantium 240V and the other
appliance overlaps.
Construct a solid oven floor of 3/8” min. thick plywood
supported by 2 x 4 or 2 x 2 runners on all sides.
The support must be level and rigidly mounted, flush
with the bottom edge of the cutout.
PREPARE THE OPENING (CONT.)
Installation over a Warming Drawer:
30”
23-1/2”
25-1/4”
17-1/2”
36-3/4”
Min.
2” Min.
(3”
recommended)
Per warming
drawer
requirement
Construct
Solid Bottom
Min. 3/8”
Plywood
Supported
by 2x4 or 2x2
Runners all
Four Sides
NOTE: Additional clearances between the cutouts
may be required. Check to be sure the oven supports
above the Warming Drawer location do not obstruct
the required interior depth and height. See Warming
Drawer installation instructions for details.
IMPORTANT: Always maintain 36-3/4” minimum height from the floor to the cutout in any single or combined
installation.