Owner's Manual
20 49-2000706 Rev. 3
INSTALLATION INSTRUCTIONS
Installation Instructions
4
 (Alternate Mounting Method) INSTALL HOOD TO SOFFIT OR CABINET 
(Cont.)
• Drill two 1/8” pilot holes at a distance of 10” from the 
back wall in the horizontal wood supports. This is the 
vertical distance between mounting keyholes and 
back wall as shown in Figure C
• Drill two more 1/8” pilot holes at a distance of 3” from 
the back wall in the horizontal wood supports. This is 
the vertical distance between mounting screw holes 
and back wall as shown in Figure C. 
• For top venting, allow minimum opening (Dim. B) to 
accommodate damper in soffit or cabinet. 
• For back venting, allow minimum opening (Dim. C) to 
accommodate damper in back wall
• Drive mounting screws (A) into the studs until they 
protrude 1/4”. This 1/4” gap will provide clearance to 
engage the keyhole slots in the top of the hood.
• The hood must also be secured to the back wall. 
Follow instruction on page 18, “Drill Bottom 
Mounting Hole Locations” section for installation to 
the back wall.
• Follow instructions on page 17, "House Wiring 
Locations" section for wiring setup.
• Lift hood onto mounting screws. Slide back against 
the rear wall.
• Pull house wiring through the knockout at the rear or 
top of the hood.
• Tighten mounting screws (A).
• Once the hood is secured to the soffit or cabinet, 
drive screws (C) to secure the hood to the back wall. 
1/4” Gap
Soffit or 
Cabinet
Back 
Wall
Engage Keyhole Slots 
and Push Back at Wall
3”
Figure C
Back Wall
10"
A
Keyholes 
for Soffit 
or Cabinet 
Mounting