Owner's Manual
49-2000706 Rev. 3 21
Installation Instructions
5
 INSTALL MOTOR
I) Align the motor exhaust with the top damper as 
shown in the Figure A for top venting. In case of 
back venting, rotate the motor 90° to align with the 
back damper as shown in Figure B.
II) Secure the motor to motor mounting plate using 
screws (D).
III) Plug the motor connector into the mating 
connector on top of the control housing.
6
 CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
 If house wiring is not 2-wire with 
a ground wire, a ground must be provided by the 
installer. When house wiring is aluminum, be sure 
to use UL approved anti-oxidant compound and 
aluminum-to-copper connectors.
• Remove junction box cover.
• Pull the house wiring through the knockout at the 
top or back of the hood and secure with the strain 
relief.
• Use UL listed wire nuts to connect incoming white 
to white, and black to black wires. 
• Loosen the green grounding screw (with grounding 
bracket) in the junction box. Loop solid copper 
house wire clockwise around the green grounding 
screw and above the bracket. Firmly tighten the 
screw over the loop. 
• Replace junction box cover and ensure wires are 
not pinched. 
NOTE: For corded installation:
Use only with range hood cord-connection kits that 
have been investigated and found acceptable for 
use with this model range hood.
Top Venting
Figure A
Back Venting
Figure B
Top Venting Installation
Motor mating 
connector location
Motor Mounting Plate
INSTALLATION INSTRUCTIONS
Grounding Bracket
Green Grounding Screw