Specification

FOR WARRANTY ISSUES OR QUESTIONS, CONTACT CAHABA AT (866) 837-2550.
©2017 CAHABA. ALL RIGHTS RESERVED.
6
30 IN. SQUARE GRATE LINEAR SHOWER DRAIN
Installation Instructions
INSTALL FLASHING
1. Lift out ashing. Remove tape, leaving tape over drain hole only. Apply
a 1/8” continuous bead of sealant around chamfer on base ange and
another bead in groove on drain base (N).
2. Apply latex-modied thin-set to mortar bed, walls and curb as needed.
Apply sealant to any preformed corners.
3. Align membrane and rmly press all areas of membrane into adhesive
on walls, oor, curb and sealant on drain base and any pre-formed
corners.
4. Fasten Flashing by nailing through top 1” of ashing to studs and/or
blocking (O).
5. Install clamping collar. Align collar with drain base under ashing.
Press rmly. Starting at one end, insert 5/8” screw through collar, punch
through ashing and screw into base. Repeat for all screws. Do not
over-tighten (O).
6. Cut Out Flashing. With a razor knife, carefully trim out ashing from
center of collar. Remove tape from drain hole (P).
X CAUTION: Do not puncture flashing outside of collar.
COMPLETE WATERPROOFING
1. Complete installation of bonded waterproong membrane (ANSI
A118.10) on shower oor. Any waterproong membrane material or
procedure can be used (vinyl, CPE membrane, roll/paint on, metal pan,
hot mop, surface Sheet Membrane, etc.).
2. Flood test as required by local codes.
3. Install Backer Board and Wall Waterproong: Install 1/2” backer board
and wall waterproong according to manufacturer’s instructions, local
plumbing codes and TCNA guidelines.
X NOTE: TCNA guidelines require waterproong or a vapor membrane be
installed on all walls.
X CAUTION: Do not puncture flashing.
(N) APPLY SEALANT
(O) FASTEN AND INSTALL CLAMPING COLLAR
(P) TRIM OUT FLASHING FROM COLLAR