Audio Mixdown Options dialog
Dialog Reference
• Fall (msecec)—the time it takes for an RMS meter to register a 20dB
fall in signal.
•Peak
• Rise (msecec)—the time it takes for a Peak meter to register a 20dB rise
in signal.
• Fall (msecec)—the time it takes for a Peak meter to register a 20dB fall
in signal.
Here are the default values for the various settings:
• Refresh Rate = 40 msec
• Peak Hold – Decay Rate = 50 msec
• Peak Hold – Hold Time = 750 msec
• RMS Rise = 300 msec
• RMS Fall = 300 msec
• Peak Rise = 0 msec
• Peak Fall = 1000 msec
Segmented Meters
The Track View and Console View checkboxes let you display the meters in
segmented fashion in the respective views.
For more information, see Metering.
Audio Mixdown Options dialog
Clicking the Mixdown Options button in the Export Video dialog opens the
Audio Mixdown options dialog. This dialog lets you control the
characteristics of the audio file you export when you export a video from
SONAR.
This dialog has the following fields:
• Preset—You can name and save a preset which includes the source
bus and all mix enable selections.
• Channel Format—choose Mono, Stereo, or Multichannel.
• Sample Rate—choose the sample rate that you want your exported
audio to use.
• Bit Depth—choose the bit depth that you want your exported audio to
use.