822 System Exclusive Data
Troubleshooting
SysxSendDelayMsecs=n
This setting causes SONAR to delay n milliseconds if it encounters an F7 in
a System Exclusive bank, but only if the line SysxDelayAfterF7=n is not
zero. The line SysxDelayAfterF7=n enables a delay between Sysx
messages, while the line SysxSendDelayMsecs=n sets the size of the
delay.
n = 60 Default value (in milliseconds)
SysxDelayAfterF7=n
This setting causes SONAR to delay Sysx transmission for a certain
amount of time if it encounters an F7 in a System Exclusive bank. This
gives some instruments the required amount of “breathing” time necessary
to process the Sysx transmission. The default delay is 1/18 of a second, but
can be changed by also adding the SysxSendDelayMsecs=n line, where n
is the number of milliseconds that the delay lasts.
The possible values of n in the line SysxDelayAfterF7=n are 0 and 1. Their
significance is as follows:
n = 0 No delay
n = 1 Delay between each Sysx message
SysxSendPacketSize=n
System Exclusive bytes are transmitted in packets, with a 1/18-second
default delay between each packet. Setting this value to a smaller number
will help slower synthesizers avoid overflowing their internal buffers. This
line sets the number of bytes between each Sysx transmit delay.
n = 1024 Default value (in bytes)
See:
Troubleshooting
What Is System Exclusive?
Troubleshooting
SONAR Is Not Receiving Sysx Messages
Make sure all your devices are connected correctly.
Make sure you have the right MIDI Input selected by using the
Options-MIDI Devices command.
Make sure that your instrument is set up to transmit System Exclusive