Install guide

CalAmp | LenderOutlook Device Install Guide
MBUD-0266v1.1 Page 7
3.3 WIRING
3.3.1 LMU-3XX
The LMU-3XX has 4 22AWG leads for its power and I/O connections. These leads are mapped as follows:
Wire
Signal
Name
Description Color Input or Output Usage
1 GND Ground Black
Ground
Serial Cable
Required
2 VCC Primary Power Input Red Power
Required
3 IN-0 Input 0 White Ignition Input
Required
4 Out-0 Output 0 Green Output to Relay
Optional
3.3.2 LMU-7XX AND LMU-8XX
The LMU-7XX and LMU-8XX have 8 22AWG leads for its power and I/O connections. These leads are
mapped as follows:
Wire
Signal
Name
Description Color Input or Output Usage
1 GND Ground Black
Ground
Serial Cable
Required
2 VCC Primary Power Input Red Power
Required
3 IN-0 Input 0 White Ignition Input
Required
4 IN-1 Input 1 Blue Input
Not used
5
IN-2
Input 2 \ Rx
Orange
Input \ Serial Rx
Not used
6 Out-0 Output 0 Green
Output to Starter
Relay
Optional
7
Out-1
Output 1
Brown
Output
Not used
8
Out-2
Output 2 \ Tx
Yellow
Output to PR buzzer
Optional