MBUD-0266v1.1    Page 17 
3.  Secure the LMU-XXX OBD-II harness connector and the OBD-II connector together with tape to 
prevent loose connections that may occur from normal vehicle operation vibration.  
Figure 11: Plugged OBD-II Connectors and Taped Connectors 
4.  Re-mount the LMU-XXX OBD-II harness connector in the vehicle’s original location. 
5.  Important: The OBD-II port provides device power, but to obtain ignition condition, you must 
connect the White Wire from the Standard Wiring Harness to True Ignition in the vehicle. 
•  Connect the White Wire from the Standard Wiring Harness to True Ignition in the vehicle. Verify that 
the wire is powered only with the key in the engine on condition, not the ACC or radio key position.  