Installation guide

LMU Users Guide
V1.0.6 December 10 2009
Copyright ©CalAmp DataCom Inc 2009
- 149 - CalAmp Proprietary & Confidential
Register
Description
8-Bit
LMU-1000
LMU-2500
LMU-4100
148
Host Port Baud Rate Selection
Description:
The S-Register determines which BAUD rate the
LMU should use for its Host Port while in Standard
mode. This value will be overridden by S131 while in
GSD mode
Settings:
4=4800
5=9600
7=19200
9=38400
10=57600
12= 115200
255 = use default (115200)
X X X
149
Send-Fail Modem Restart Count Threshold
Description:
If the LMU is unable to send a message the number
of times in this S-register, it will reset the wireless
modem
Settings:
The number of Send Fails to wait before resetting the
wireless modem ranging from 1 to 255. 0 disables
this feature.
X X X X
150
Alternate Modem Select
Description:
This S-Register controls which modem driver the
LMU uses to connect to a wireless device when using
Comm Index 1.
Each driver decides what type of modem is being
used for the LMU’s data connectivity and if the LMU
can poll the modem for network information (eg
RSSI). The default Baud rate and Dial strings are also
chosen by the driver.
Settings:
LMU Drivers
3 iDEN LMU 19200, ATDT 0, PPP, Motorola
iDEN StatusTC990569
5 GPRS LMU 57600,ATD*99***1#, WaveCom
11 CDMA LMU CDMA 1xRTT Modem
Kyocera M200
14 iDEN LMU 19200, ATDT 0, PPP, CMUX
StatusTC990599
15 GPRS LMU 115200, ATD*99***1#, PPP,
Siemens
17 - CDMA LMU CDMA 1xRTT Modem
WaveCom Q2438
18GPRS LMUATD*99***1#, PPP,
Siemens/Cinterion MC55
X