Installation guide
LMU Users Guide
V1.0.6 December 10 2009
Copyright ©CalAmp DataCom Inc 2009
- 154 - CalAmp Proprietary & Confidential
Register
Description
8-Bit
LMU-1000™
LMU-2500™
LMU-4100™
160
Aux Serial Port Mode Control
Description:
This S-Register controls what mode the LMU’s Aux
port is in.
Settings:
0 = Generic Serial Device (GSD)
1 = Enabled NMEA GGA Message Output
Bit 4 – RMC Message
- Set = Enable NMEA RMC message output
- Cleared = Disable NMEA RMC message output
X
161
Aux Serial Port Baud Rate
Description:
This S-Register will set the LMU’s Host Port Baud
rate while not in Standard mode
Settings:
4 = 4800
5 = 9600
7 = 19200
9 = 38400
10 = 57600
12 = 115200
X
162
Aux Serial Port Word Definition (Parity, Stop Bits, Word
Size)
Description:
This S-Register will set the LMU’s Host Port word
definition while not in Standard mode
Settings:
Bit 0 – Bit 1 – Word Size
0 = 5 bits
1 = 6 bits
2 = 7 bits
3 = 8 bits
Bit 2 – Stop Bits
- Set = 2 Stop Bits
- Cleared = 1 Stop Bit
Bit 3 – Parity
- Set = Parity Enabled
- Cleared = No Parity
Bit 4 – Parity Type
- Set = Even Parity
- Cleared = Odd Parity
X