Installation guide
LMU Users Guide
V1.0.6 December 10 2009
Copyright ©CalAmp DataCom Inc 2009
- 32 - CalAmp Proprietary & Confidential
To disable this mode, you would use:
ATS130=0
5.1.4.3 MDT Mode – Serial Port settings
The MDT Mode serial port settings are independent from the Host Port Host Mode
settings. The MDT mode settings are controlled by 2 S-Registers, 131 and 132. These
register control the BAUD Rate, Data Bits, Parity and Stop Bits settings for MDT mode.
These changes do not affect the settings of S-148 or the +IPR command (i.e. the host port
baud rate).
The MDT mode BAUD Rate is controlled by S-Register 131 and supports the following
data rates:
• 4800 BAUD (ATS131=4)
• 9600 BAUD (ATS131=5)
• 19200 BAUD (ATS131=7)
• 38400 BAUD (ATS131=9)
• 57600 BAUD (ATS131=10)
• 115200 BAUD (ATS131=12)
To change the Data Bits, Parity and Stop Bit settings, you would use S-Register 132. The
follow table describes each of the available combinations:
Data Bits
Parity
Stop Bits
S-132 Setting
8
None
2
7
8
None
1
3
8
Even
2
31
8
Even
1
27
8
Odd
2
15
8
Odd
1
11
7
None
2
6
7
None
1
4
7
Even
2
30
7
Even
1
26
7
Odd
2
14
7
Odd
1
10
6
None
2
5
6
None
1
1
6
Even
2
29
6
Even
1
25
6
Odd
2
13
6
Odd
1
9
5
None
2
4
5
None
1
0
5
Even
2
28
5
Even
1
24
5
Odd
2
12
5
Odd
1
8