Installation guide
LMU Users Guide
V1.0.6 December 10 2009
Copyright ©CalAmp DataCom Inc 2009
- 39 - CalAmp Proprietary & Confidential
• Attempt to send the User Message. If the message cannot be sent, or the log is
already active, the User Message is logged.
• Immediately log the User Message
• Route the User Message (contents only) to the SMS Destination Address
• Route the User Message (contents only) to the last phone number of an incoming
SMS message
With the last two options the contents of any incoming SMS messages will be routed to the
serial device.
The Message Disposition is controlled by S-Register 167. The settings are as follows:
• 1 or 2 = Send Message, Log if Send Fails
• 3 = Log Message
• 7 = Route Incoming (Client to LMU) SMS messages to the Aux Serial Port. Route all
User Messages to the SMS Destination Address
• 8 = Route Incoming (Client to LMU) SMS messages to the Aux Serial Port. Route all
User Messages to the last phone number that sent the LMU a message
5.2.2.7 MDT Mode – Message Count Limit
The Message Count Limit for the Aux port is defined by S-169. Unlike the Host Port, the
Aux Port limit does not offer a scaling option and therefore only ranges from 0-255
messages. For example, to send every 10
th
message received on the Aux Port, you would use:
ATS169=10
To send every 150th message, you would use:
ATS169=150