Operating Guide

G Series Gas Grills
LTR50001050, Rev. E
Built-in Construction
www. ca l a me b bq . c o m
5
Plan the installation so that the electrical connection,
gas shut-off valve, and pressure regulator are
accessible inside the base enclosure. The gas valve
shall be readily accessible for hand operation. A door
on the enclosure to gain access to the gas valve is
acceptable, provided it is non-locking and can be
opened without the use of tools.
The design of the outdoor cooking enclosure must allow
the LP gas cylinder to be connected and disconnected
and the connections inspected and tested.
There must be a minimum clearance of 2 inches
(51mm) between the oor of the LP-gas cylinder
enclosure and the ground.
Model Description Width Depth Height
BBQ09G03 G3 three burner grill 23 3/8” 22” 9 ¼”
BBQ08G04 G4 four burner grill 31” 22” 9 ¼”
BBQ09G05 G5 ve burner grill 38 7/8” 22” 9 ¼”
W
ID
T
H
W
ID
T
H
W
ID
T
H
W
ID
T
H
Minimum
Clearance
12” Minimum Distance
Between Grill and Side Burner
Minimum
Clearance
Screen Vents
WIDTH
W
ID
T
H
WIDTH
DEPTH
WIDTH
WIDTH
DEPTH
WIDTH
WIDTH
WIDTH
DEPTH
DEPTH
DEPTH
HEIGHT
HEIGHT
HEIGHT
Burner
Locking Pin
Burner
Locking Pin
Model Description Width Depth Height
BBQ08954P Deluxe Side by Side Burner 25 ¼” 12 ½” 7 ¼”
BBQ08899P Deluxe Double Side Burner 12 ¼” 22” 7 ¼”
The dimensions shown below are for Cal Flame appliances only.