For proper ventilation, the base structure must be constructed using one of two designs:
An enclosure having four sides, a top, and bottom
1
2
An enclosure with one side open
The second type of enclosure must be constructed
with the following specications:
At least two ventilation openings at cylinder
•
valve level shall be provided in the side wall,
equally sized, spaced at 180 degrees and
unobstructed.
Each opening shall have a total free area of not •
less than 10 square inches (254 square mm).
Ventilation openings shall be provided at oor •
level and shall have a total free area of not less
than 10 square inches (254 square mm). If the
ventilation openings at oor level are in a side
wall, there shall be at least two openings. The
bottom of the openings shall be at oor level and
the upper edge no more than 5 inches (127mm)
above the oor. The openings shall be equally
sized, spaced, and unobstructed.
LP-gas cylinders should be ventilated by •
openings at the level of the cylinder valve and
the oor level. The effectiveness of the openings,
for purposes of ventilation, shall be determined
with the LP-gas supply cylinder in place.
Enclosure Ventilation