OM-2218 Page 22
5-3. Voltmeter/Ammeter Help Displays
.All directions are in reference to the
front of the unit. All circuitry referred to
is located inside the unit.
1 Help 0 Display
Indicates a malfunction in the thermal
protection circuitry located on the left side of
the unit. Contact a Factory Authorized Ser-
vice Agent if this display is shown.
2 Help 1 Display
Indicates a malfunction in the primary pow-
er circuit. Contact a Factory Authorized
Service Agent if this display is shown.
3 Help 2 Display
Indicates a malfunction in the thermal
protection circuitry located on the left side of
the unit. Contact a Factory Authorized Ser-
vice Agent if this display is shown.
4 Help 3 Display
Indicates the left side of the unit has over-
heated. The unit has shut down to allow the
fan to cool it (see Section 3-2). Operation
will continue when the unit has cooled.
5 Help 4 Display
Indicates a malfunction in the thermal
protection circuitry located on the right side
of the unit. Contact a Factory Authorized
Service Agent if this display is shown.
6 Help 5 Display
Indicates the right side of the unit has over-
heated. The unit has shut down to allow the
fan to cool it (see Section 3-2). Operation
will continue when the unit has cooled.
7 Help 6 Display
Indicates that the input voltage is too low
and the unit has automatically shut down.
Operation will continue when the voltage is
within the operating range (±15%). Have an
electrician check the input voltage if this dis-
play is shown.
8 Help 7 Display
Indicates that the input voltage is too high
and the unit has automatically shut down.
Operation will continue when the voltage is
within the operating range (±15%). Have an
electrician check the input voltage if this dis-
play is shown.
9 Help 8 Display
Indicates a malfunction in the secondary
power circuit of the unit. Contact a Factory
Authorized Service Agent if this display is
shown.
10 Help 9 Display
Indicates a malfunction in the thermal
protection circuitry located on the right side
of the unit. Contact a Factory Authorized
Service Agent if this display is shown.
11 Help 10 Display
Indicates gun trigger is depressed. Release
trigger to continue.
2
AV
3
AV
4
AV
HE.L P1
HE.L P2
HE.L P3
5
AV
HE.L P4
6
AV
HE.L P5
7
AV
HE.L P6
8
AV
HE.L P7
9
AV
HE.L P8
1
V
HE.L P0
10
AV
HE.L P9
11
AV
HE.L P10
A