3. Mechanical Installation
3.1 General
• The Fenner QD:Neo should be mounted in a vertical position only on a flat, flame resistant vibration free
mounting using the integral holes or DIN rail clip (Frame Size 2 only).
• The drive must be installed in a pollution degree 1 or 2 environment only.
• Do not mount flammable material close to the Fenner QD:Neo
• Ensure that the minimum cooling air gaps, as detailed in section 3.5 and 3.8 are left clear
• Ensure that the ambient temperature range does not exceed the permissible limits for the Fenner QD:Neo
given in section 10.1
• Provide suitable clean, moisture and contaminant free cooling air sufficient to fulfil the cooling
requirements of the Fenner QD:Neo
3.2 Before Installation
• Carefully Unpack the Fenner QD:Neo and check for any signs of damage. Notify the shipper immediately if any
exist.
• Check the drive rating label to ensure it is of the correct type and power requirements for the application.
• Store the drive in its box until required. Storage should be clean and dry and within the temperature range
–40°C to +60°C.
3.3 UL Compliant Installation
Note the following for UL compliant installation:
• The drive can be operated within an ambient temperature range as stated in section 10.1
• For IP20 units, installation is required in a pollution degree 1 environment
• For IP55 units, installation in a pollution degree 2 environment is permissible
• UL Listed ring terminals / lugs must be used for all bus bar and grounding connections
3.4 Mechanical Dimensions and Mounting - IP20 Units
Drive
Size
A B C D E F G H I J
mm in mm in mm in mm in mm in mm in mm in mm in mm in mm in
2 221 8.70 204 8.15 137 5.39 209 8.23 5.3 0.21 185 5.91 112 4.29 63 2.48 5.5 0.22 10 0.39
3 261 10.28 246 9.69 - - 247 9.72 6 0.24 205 6.89 131 5.16 80 3.15 5.5 0.22 10 0.39
Control terminal torque settings: All Sizes: 0.8Nm Power Terminal Torque Settings: All sizes: 1Nm