3.8 Guidelines for Mounting (IP55 Units)
• Before mounting the drive, ensure that the chosen location meets the environmental condition requirements for
the drive shown in section 10.1
• The drive must be mounted vertically, on a suitable flat surface
• The minimum mounting clearances as shown in the table below must be observed
• The mounting site and chosen mountings should be sufficient to support the weight of the drive
Drive
Size
X
Above and Below
Y
Either Side
mm in mm in
4 200 7.87 10 0.39
5 200 7.87 10 0.39
6 200 7.87 10 0.39
7 200 7.87 10 0.39
Note:
Typical drive heat-losses are 3% of operating load conditions
Above are guidelines only and the operating ambient temperature of
the drive MUST be maintained at all times.
Drive
Size
A B C D E F G H I
mm in mm in mm in mm in mm in mm in mm in mm in mm in
4 440 17.32 418 16.46 423 16.65 8 0.315 240 9.449 171 6.732 110 4.331 4.25 0.167 7. 5 0.295
5 540 21.26 515 20.28 520 20.47 8 0.315 270 10.63 235 9.252 175 6.89 4.25 0.167 7. 5 0.295
6 865 34.06 830 32.68 840 33.07 10 0.394 330 12.99 330 12.99 200 7.874 5.5 0.217 11 0.433
7 1280 50.39 1245 49.02 1255 49.41 10 0.394 360 14.17 330 12.99 200 7.874 5.5 0.217 11 0.433
Control terminal torque settings: All Sizes: 0.5Nm
Power Terminal Torque Settings: Frame Size 4: 1.2-1.5Nm
Frame Size 5: 2.5 - 4.5Nm
Frame Size 7: 8Nm
Frame Size 8: 8Nm
3.7 Mechanical Dimensions (IP55 Units)
Using the drive as a template, or the dimensions shown above, mark the locations required for drilling
The drive should be mounted using M8 (Frame sizes 4 & 5) or M10 (Frame Sizes 6 & 7) mounting bolts
G
F
H
G
D
C
B
I
A
E
X
X
Y Y
Z