Hardware manual

55
FUJITSU SEMICONDUCTOR CONFIDENTIAL
MB96630 Series
DS704-00012-1v0-E
6. Low Voltage Detection Function Characteristics
(V
CC
= AV
CC
= 2.7V to 5.5V, V
SS
= AV
SS
= 0V, T
A
= - 40°C to + 125°C)
Parameter Symbol Conditions
Value
Unit
Min
Typ
Max
Detected voltage
*1
V
DL0
CILCR:LVL = 0000
B
2.70
2.90
3.10
V
V
DL1
CILCR:LVL = 0001
B
2.79
3.00
3.21
V
V
DL2
CILCR:LVL = 0010
B
2.98
3.20
3.42
V
V
DL3
CILCR:LVL = 0011
B
3.26 3.50 3.74 V
V
DL4
CILCR:LVL = 0100
B
3.45
3.70
3.95
V
V
DL5
CILCR:LVL = 0111
B
3.73 4.00 4.27 V
V
DL6
CILCR:LVL = 1001
B
3.91 4.20 4.49 V
Power supply voltage
change rate
*2
dV/dt - - 0.004 - + 0.004
V/µs
Hysteresis width V
HYS
CILCR:LVHYS=0 - - 50 mV
CILCR:LVHYS=1 80 100 120 mV
Stabilization time T
LVDSTAB
- - - 75
µs
Detection delay time
t
d
-
-
-
30
µ
s
*1: If the power supply voltage fluctuates within the time less than the detection delay time (t
d
), there is a
possibility that the low voltage detection will occur or stop after the power supply voltage passes the
detection range.
*2: In order to perform the low voltage detection at the detection voltage (V