Owner`s manual
NATURAL GAS REQUIREMENTS
Natural Gas Requirements
Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the
firepit/fireplace is manufactured for.
IMPOR
TANT WARNING: All Cal Flame firepit/fireplaces are manufactured with the highest
regard to safety. For this reason, Cal Flame firepit/fireplaces are either
manufactured to operate on Liquid Propane (LP) or Natural Gas
(NG) and cannot be conver
ted. To verify the firepit/fireplaces
operating fuel, remove the bottom drip pan and check serial number
label on the left. Either LP or NG will be marked on the operating
tab, indicating the proper operating fuel.
Attempting to convert Cal Flame firepit/fireplaces from one fuel to
another may result in serious injury and void the warranty coverage.
IMPOR
TANT: Never connect the firepit/fireplace to an unregulated gas supply.
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a-1998. Installation in Canada must be in accordance with the standard
CAN/CGA-B149.2, Propane Installation Code.
NATURAL Gas Connection: (Must be performed by a licensed contractor or local gas company representative).
Ensure that the service supplying the firepit/fireplace is fitted with a shut off valve conveniently positioned to
the firepit/fireplace and giving ease of access.
Your Cal Flame Firepit/fireplace for use with Natural Gas comes equipped with its own regulator which MUST
NOT be removed. If this regulator needs to be replaced, use only the type specified by Cal Flame for this
appliance.
1. Remove the rear panel from the firepit/fireplace to gain access to the regulator and gas connection point.
2. Connect a suitable flex connector to the firepit/fireplace regulator.
Owner’s Manual Page 9
Owner’s Manual Natural Gas Requirements