LP Gas Manifold Pressure
For plumbed-in LP installation, use a convertible regulator and set it for LP gas.
LP Gas Supply Pressure
LP Gas Supply Pressure
Maximum line pressure for plumbed-in propane is 14” W.C psi (3.5 kPa). Minimum line pressure for propane is
11” W.C.
LP Gas Pressure Regulator
The unit must be used with the gas pressure regulator. The regulator will control and maintain a uniform gas
pressure in the manifold. The burner orifices have been sized for the gas pressure delivered by the regulator.
LPG Cylinder Specification
Any LP gas supply cylinder used with this firepit/fireplace must be approximately 12 inches in diameter and 18
inches high. The maximum fuel capacity is 20 lbs. of propane, or 5 gallons. Full cylinder weight should be
approximately 38 lbs. (43.7 lbs. nominal water capacity.) Always use the cylinder dust cap on the cylinder valve
outlet during transport and when the cylinder is not connected to the firepit/fireplace.
Transporting the LP Gas Supply Cylinder
Only one cylinder should be transported at a time. Transport cylinder in an upright and secure manner with
control valve turned off and the dust cap in place.
LP Gas Requirements Owner’s Manual