Specifications
2008 Fireplace and Firepit Owner’s Manual Page 9
LTR20081006, Rev. A
Installation and Assembly
Natural Gas Conversion
For Both Fireplaces or Fire Pits
CAUTION: This service is to be completed only by an
authorized gas appliance installer. Do not attempt this
conversion on your own as there is risk of serious injury
or death.
To The Authorized Gas Appliance Installer:
All Cal-Flame Gas Log Fireplaces are shipped from the
factory equipped to burn on liquid propane fuel. Enclosed
with this kit is a natural gas conversion kit to allow the
owner to convert and operate this unit on natural gas. To
perform this conversion, follow the directions below and
to the local regulation standards in your area.
Make sure unit is not in operation and is cool enough
to perform this service. Shut off and disconnect
propane fuel source at the regulator end.
Carefully remove the storage cover, lava rocks and
re logs. Turn unit over to access hose connections
underneath.
While holding the propane orice in place with a
wrench, unscrew brass tting on fuel inlet hose.
Unscrew propane orice and remove.
Using the new brass natural gas orice re-install
the parts in the same sequence. Turn the protective
screen / air intake sleeve to allow a controlled
amount of air ow through the screen and into the
fuel supply tube. Flame should have good retention.
For a proper burn and as a general rule there should
be less air ow required and therefore the air intake
screen should be nearly closed when re-installed.
This can be adjusted later to create a clean and
desired ame.
1.
2.
3.
4.
Refer to photo below for proper placement of parts.
The washer should insert next to the protective
screen cover, then the spring is to be aligned with
the hole and nally the natural gas orice is to be
threaded into the end of the fuel inlet leading into the
burner. Once tight the other brass tting connection
can be made from the fuel line tted between the
valve and the orice.
Connect natural gas supply hose, (not included with
kit), from supply source. Test for leaks.
Once the conversion is completed and leak tested,
reload the replace or repit with the lava rocks and
re logs. Test the unit while in place and verify it
works properly. If ame from burner is not properly
adjusted you can adjust air intake by turning the
protective screen cover and air intake sleeve on the
fuel supply tube.
5.
6.
7.
Applies to the following replaces and re pits:
FRP-1000 FPT-50 FPT-650
FRP-1100 FPT-80 FPT-800
FRP-1500 FPT-90 FPT-900
FRP-2000 FPT-95 FPT-951
FRP-3000 FPT-125 FPT-955
FRP-3100 FPT-600 FPT-1100
FRP-3200
FRP-4300
FRP-4400