Specifications

9
OPERATION OF DURA-CYL MCR 160 / 180 / 200 / 230 / 265MP
25
General
This section of the manual deals with the Dura-Cyl MCR
1
60 MP, Dura-Cyl MCR 180 MP, Dura-Cyl MCR 200 MP,
Dura-Cyl MCR 230 MP and Dura-Cyl MCR 265 MP.
They will be referred to in this section as liquid cylinders.
These liquid cylinder models are functionally the same
and only vary in capacity. They are designed to transport,
store and delivery liquid oxygen, nitrogen or argon as
a cryogenic liquid or gas. The common application
for these liquid cylinders is to provide gas at pressures
around 100 psi (6.9 bar). The liquid cylinder will build
and maintain pressure at the pressure control regulator
setting of 125 psi (8.6 bar). If the pressure exceeds
1
40 psi (9.7 bar) the economizer portion of the regulator
will supply gas to the receiving equipment to reduce
the cylinder pressure. A continuous gas flow can be
automatically provided from these cylinders.
Liquid can be withdrawn from these liquid cylinders
in the same manner that was described in section 8
Cryo-Cyl LP.
%
&






'AS 5SE
6ALVE






6ENT
6ALVE







0RESSURE "UILDING
6ALVE







,IQUID &ILL
6ALVE




