Specifications
Page 2
SPECIFICATIONS
Model No. GCS241353 GCS241603
*
ARI Standard
Total cooling capacity Btuh (kW) 119,000 (34.9) 144,000 (42.2)
*ARI
S
tan
d
ar
d
210/240 Ratin
g
s
Total unit watts 11,780 15,500
210/240
Ratings
or
St d d 360 R ti
EER (Btuh/Watts) 10.1 9.3
or
Standard 360 Ratings
Integrated Part Load Value 9.8 10.3
ARI Standard 270 SRN (Bels) 8.4 8.8
Refrigerant (22) Charge
Stage 1 11 lbs. 0 oz. (4.99 kg) 11 lbs. 8 oz. (5.22 kg)
Refrigerant (22) Charge
Stage 2 11 lbs. 0 oz. (4.99 kg) 11 lbs. 8 oz. (5.22 kg)
Blower wheel nominal dia. x width in. (mm) 15 x 15 (381 x 381) 15 x 15 (381 x 381)
Eva
p
orator Blower
Ft
Nominal motor hp (W) 3 (2238) 3 (2238)
Evaporator
Blower
and
Di S l ti
Factory
Installed
Maximum usable hp (W) 3.45 (2574) 3.45 (2574)
and
Drive Selection
Installed
***Drives
Voltage & phase 208/230/460v or 575v3ph 208/230/460v or 575v3ph
Drives
RPM range 730 950 730 950
Evaporator
Net face area sq. ft. (m
2
) 9.46 (0.88) 11.9 (1.11)
Evaporator
Coil
Tube diameter in. (mm) & No. of rows 3/8 (9.5) 4 3/8 (9.5) 3
C
o
il
Fins per inch (m) 12 (472) 12 (472)
Condenser
Net face area sq. ft. (m
2
) 30.25 (2.81) 30.25 (2.81)
Condenser
Coil
Tube diameter in. (mm) & No. of rows 3/8 (9.5) 2 3/8 (9.5) 2
C
o
il
Fins per inch (m) 20 (787) 20 (787)
Diameter in. (mm) & No. of blades (2) 22 (559) 5 (2) 22 (559) 4
Condenser
Air volume cfm (L/s) 8800 (4155) Total 8800 (4155) Total
Condenser
Fans
Motor horsepower (W) (2) 1/2 (373) (2) 1/2 (373)
Motor watts 995 Total 995 Total
Input (low) Btuh (kW) 170,000 (49.8) 170,000 (49.8)
Sea Level
TSt
Output (low) Btuh (kW) 132,500 (38.8) 132,500 (38.8)
Two Stage
Heating Capacity
Input (High) Btuh (kW) 270,000 (79.1) 270,000 (79.1)
H
ea
ti
ng
C
apac
it
y
(
Natural Gas Onl
y)
Output (High) Btuh (kW) 216,000 (63.3) 216,000 (63.3)
(Natural
Gas
Only)
A.G.A./C.G.A. Thermal Efficiency 80% 80%
Input (low) Btuh (kW) 170,000 (49.8) 170,000 (49.8)
Sea Level
TSt
Output (low) Btuh (kW) 132,500 (38.8) 132,500 (38.8)
Two Stage
Heating Capacity
Input (High) Btuh (kW) 236,250 (69.2) 236,250 (69.2)
H
ea
ti
ng
C
apac
it
y
(
**LPG/Pro
p
ane Gas Onl
y)
Output (High) Btuh (kW) 192,500 (56.4) 192,500 (56.4)
( LPG/Propane
Gas
Only)
A.G.A./C.G.A. Thermal Efficiency 81.5% 81.5%
Input (low) Btuh (kW) 170,000 (49.8) 170,000 (49.8)
High Altitude
TSt
Output (low) Btuh (kW) 132,500 (38.8) 132,500 (38.8)
g
Two Stage
Heating Capacity
Input (High) Btuh (kW) 254,000 (74.4) 254,000 (74.4)
H
ea
ti
ng
C
apac
it
y
(
Natural Gas Onl
y)
Output (High) Btuh (kW) 203,200 (59.5) 203,200 (59.5)
(Natural
Gas
Only)
C.G.A. Thermal Efficiency 80% 80%
Input (low) Btuh (kW) 170,000 (49.8) 170,000 (49.8)
High Altitude
TSt
Output (low) Btuh (kW) 132,500 (38.8) 132,500 (38.8)
g
Two Stage
Heating Capacity
Input (High) Btuh (kW) 235,000 (68.9) 235,000 (68.9)
H
ea
ti
ng
C
apac
it
y
(
**LPG/Pro
p
ane Gas Onl
y)
Output (High) Btuh (kW) 191,525 (56.1) 191,525 (56.1)
( LPG/Propane
Gas
Only)
C.G.A. Thermal Efficiency 81.5% 81.5%
Gas Suppl
y
Natural 3/4 (19) 3/4 (19)
Gas
Supply
Connections fpt in. (mm)
**LPG/Propane 3/4 (19) 3/4 (19)
Recommended Gas
Natural 7 (1.7) 7 (1.7)
Recommended
Gas
Supply Pressure wc. in. (kPa)
**LPG/Propane 11 (2.7) 11 (2.7)
Condensate drain size mpt in. (mm) PVC 1 (25.4) 1 (25.4)
No. & size of filters in. (mm) (4) 16 x 25 x 2 (406 x 635 x 51) (4) 20 x 25 x 2 (508 x 635 x 25)
Net weight of basic unit lbs. (kg) (1 Package) 1254 (569) 1313 (596)
Electrical characteristics 208/230v to 575v 60 hertz 3 phase
Sound Rating Number in accordance with ARI Standard 270.
*Rated in accordance with ARI Standard 210/240 or 360; 95F (35F) outdoor air temperature and 80F (27C) db/67F (19C) wb entering evaporator air.
**For LPG/Propane units a field conversion kit is required and must be ordered extra. See Optional Accessories table.
***Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors
furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the
service factor limitations outlined on the motor nameplate.