Technical data
312013 17
Operation
Setup Parameters
NOTE: If the related alarm output is enabled, the
values set for the Batch Totalizer Target, Maintenance
Totalizer Target, and Flow Rate Maximum and Mini-
mum Thresholds determine when an external alarm
will be signaled. See Alarm Outputs on page 18.
A1 – Batch Totalizer Units
Select liters (L), cubic centimeters (cc), gallons (gal),
or ounces (oz) for units of measure. The default setting
is cc. Use the up
or down arrow buttons to
scroll through the selections. Press the enter
button to enter the selection.
cc
L
gal
oz
A2 – Batch Totalizer Target Value
Set a target value for the batch totalizer that will alert a
user in Run Mode, viewing the batch totalizer screen,
that a batch is complete. The default setting is 0.0.
Repeatedly press the up arrow button until the
desired value appears for the selected digit.
cc
Press the down arrow button to move to the next
digit.
Continue using the arrow buttons to set each digit until
the entire number is set to the desired value.
cc
NOTE: Press the reset button to zero the entire
numerical value.
Press the enter button to enter the selection.
A3 – Batch Totalizer Type
Select t1, t2, or t3 for the batch totalizer type. The
default setting is t1, which sets the display to count up
from zero to the target value and automatically reset
when the target is reached.
t1: Count Up, auto reset to zero when target value
is reached.
t2: Count down, auto reset to target value when
counter is zero.
t3: Count up, manual reset.
cc
b1 – Maintenance Totalizer Units
Follow the same process as setting the A1 parameter.
cc
L
gal
oz
b2 – Maintenance Totalizer Target Value
Set a target value for the maintenance totalizer that will
alert a user in Run Mode, viewing the maintenance
totalizer screen, when it is time to do preventative
maintenance on the fluid handling system. Follow the
same process as setting the A2 parameter.
cc
C1 – Grand Totalizer Units
The Grand Totalizer cannot be reset. The reading
shows the total amount of fluid that has passed
through the unit since it was started up. To set the
units, follow the same process as setting the A1 pa-
rameter.
cc