Technical Data
Display Parameters
Display updated in approximately 1/2 sec intervals.
D Grand Totalizer
D Selectable Units (L, gal, cc, oz)
D Count Up
D Backed up to non-volatile memory
D Maximum displayed value: “999999”
D Maximum stored value: 429,496,729.5 cc
(accessible with Modbus)
D Batch Totalizer
D Selectable Units (L, gal, cc, oz)
D Count Up or Down
D Settable Target
D Maximum displayed value: “99999.9”
D Maximum stored value: 429,496,729.5 cc
(accessible with Modbus)
D Auto or Manual Reset
D Alarm when Target value is reached
causes flashing Icon and output active
D Preventative Maintenance Totalizer
D Selectable Units (L, gal, cc, oz)
D Count Up
D Settable Target
D Maximum displayed value: “99999.9”
D Maximum stored value: 429,496,729.5 cc
(accessible with Modbus)
D Manual Reset
D Alarm when Target value is reached
causes flashing Icon and output active
D Flow Rate
Display update time: 1 sec.
Sleep Mode
D To conserve battery power, if no external
power supply is connected, the Informer will
enter Sleep Mode after 5 minutes of no activity
on the front panel push buttons.
D The Informer will leave Sleep Mode when flow
is detected.
Software Upgrades
Software upgrades are performed by replacing the
programmable chip on the circuit board.
Model 243312 Meter
See manual 308778 for meter technical data.