Technical data

8 312013
Installation
Flow Meter Installation
Refer to Fig. 2 to locate and install the flow meter,
connectors, and fluid shutoff valves.
D Flow volume can only be measured at the
location where the flow meter is installed.
D Install a check valve to prevent back-flow. The
arrows on the flow meter and check valve
show the direction of fluid flow.
D The shutoff valves allow you to isolate the
meter for service.
Avoid having dust or foreign matter enter the flow
meter by taking the following precautions:
D Thoroughly flush the fluid supply lines before
installing the flow meter.
D When installing fittings, make sure that no
sealing tape overlaps into the inside of the
pipe.
D Install a 100 mesh fluid filter upstream of the
flow meter.
Calibrate the meter as instructed on page 19 before
using the meter for production.
Refer to the Dimensional Drawings on page 37 and
Technical Data on page 38 for equipment specifica-
tions.
Fig. 2
Informer Display
Flow Meter
Fluid Shutoff Valve
on inlet side
Fluid Shutoff Valve
on outlet side
Fluid Line
Check Valve
9632A