Service manual
107
SEP 2006
Ver. 1.1
DP-8020E/8020P/8016P
Note:
1. Wet Cloth represents a soft cloth saturated with water.
For stubborn toner accumulation, wipe with a soft cloth saturated with Isopropyl Alcohol first, then
follow up with a soft cloth saturated with water.
2. The Maintenance Cycle is based on the Counter Information for each individual module.
To verify the counter information, print the Total Counter List using the Service Mode: F7 - Electronic
Counter - 00 (List Print).
3. Cleaning, Replacement, and Adjustment Cycle (Sheet) are based on using Panasonic's recommended
standard paper, and supplies. These cycles may vary with the kind of paper used, Paper size,
orientation, print duty, continuous/interval print, and/or ambient conditions.
• Total Counter View Mode on the LCD
The Total Counter can be displayed on the Panel Display by pressing "COPY SIZE", and "PAPER TRAY"
keys simultaneously in Standby mode for quick reference.
• LCD Display Brightness Adjustment
To adjust the brightness of the LCD display, press and while holding down the "CLEAR" key, keep
pressing the "ORIGINAL SIZE", or the "COPY SIZE" key until the desired brightness is achieved.
ORIGINAL SIZE: Dimmer
COPY SIZE : Brighter
29 Charge Corona Case 1444 60K - - Refer to
2.2.5.
F7-07
30 Charge Wire 1443 10K
By Customer
- 60K
31 Cleaning Blade 1408 - - 60K
32 Front Cleaning Felt 1410 - - 60K
33 Rear Cleaning Felt 1411 - - 60K
34 Cleaning Sponge 1412 - - 60K
35 Splash Prevention
Sheet
1415 - - 60K
Fuser Unit
36 Fuser Roller 1115 60K
Water
1
120K
Refer to
2.2.6.
F7-02
37 Pressure Roller 1021 60K
Water
1
240K
38 Fuser Roller Bushing 1114 - - 120K
39 Pressure Roller
Bushing
1020 - - 240K
40 Thermistor
Assembly
1125 60K Dry soft cloth 120K
41 Fuser Lamp 1116 - - 240K
42 Separator 1109 60K Dry soft cloth 120K
43 Exit 2 Roller 1104 60K
Water
1
-
Main Unit
44 Ozone Filter 825 - - 240K
Refer to
2.2.13.
F7-02
45 Toner Spill Tray 1202 60K - -
No.
Mechanical Parts
Ref.
No.
Cleaning Replacement/Adjustment
Ref.
Counter
Cycle
(Sheet)
Method
Cycle
(Sheet)
Procedure
TOTAL COUNTER
1234