<Adjustment 2: Alternate method>
It is delicate method as a factory adjustment.
Only when it can not be fixed by the adjustment 1.
When the printed image is skewed as illustrated.
(1) Mark the original position of the Plate before
making any adjustments.
(2) Loosen 2 Screws.
(3) Adjust the Plate to left, and recheck the
Document Skewing. Readjust as needed.
When the printed image is skewed as illustrated.
(4) Loosen 2 Screws.
(5) Adjust the Plate to right, and recheck the
Document Skewing. Readjust as needed.
(6) Perform the Service Mode F6-03 to adjust the
Top field, if necessary.