Note 1: Continuous Polling (Station Mode)
This feature allows you to store, or add documents into a polled file in memory.
To enable the Continuous Polling feature set Function Parameter No. 003 to "2:Station".
The last Program Key will be assigned with the “Store 4 Poll” Key name automatically
and cannot be changed.
To prepare the document(s) to be polled, simply place the document(s) on the ADF, or Platen
and then press the Program Key to store, or add the document(s) into a polled file.
(Note: If a regular polled file is stored in memory, the Program Key for Continuous Polling will
not be accepted.)
Note 2: Function Parameter No. 070 (Line Error)-Transmit condition of RTP/PIP, or RTN/PIN
Note 3: Function Parameter No. 071 (Total Error)-Transmit condition of RTP/PIP, or RTN/PIN
Note 4: The default setting of parameters depends on the country’s specifications, or regulations. Print the
Function Parameter List to confirm the default settings.
124 ~
199
Not Used
Signal
Setting
1:128 2:256 3:512 4:1024 5:2048 6:Off
MCF/PIP 0-31 0-63 0-127 0-255 0-511 Always
RTP/PIP 32-63 64-127 128-255 256-511 512-1023 -
RTN/PIN 64-127 128-255 256-511 512-1023 1024-2047 -
Signal
Setting
1:5% 2:10% 3:15% 4:20%
MCF/PIP 0-2 0-4 0-7 0-9
RTP/PIP 3-4 5-9 8-14 10-19
RTN/PIN 5- 10- 15- 20-
Function Parameter Table