Service manual

330
SEP 2006
Ver. 1.1
DP-8020E/8020P/8016P
8 Options and Supplies
8.1. Service Notes "Firmware Update" for PCL or PS Option Installation
for DP-8020/8016
To use PCL (DA-PC820), or PS (DA-MC820) option individually, changing to Type B, or Type D SC
firmware is required. The required firmware is on the CD included with the options.
Note:
The 8 MB Expansion Board (DA-EM600) must be installed for the printer controllers above to function.
The only time a DA-EM600 is needed is, if you are installing the PostScript (PS), or PCL option.
Before proceeding, it is important to determine the Final Configuration of your machine in order to correctly
identify the required firmware from the table below. Carefully read, and follow the Installation Instructions for
the appropriate option.
The firmware for SC, and SPC must be updated in this sequence as a set. Please update the firmware with
the latest version as a set by referring to the following table.
Firmware Version Table
Main Unit Firmware Code Updating Instructions
1. Updating through a LAN Port (The Quickest, and Most Easiest Method)
The firmware code can be easily updated when the main unit is connected to a LAN.
The Network Firmware Update Tool can also be used by connecting to the machine using a crossover
cable, if the unit is not connected to a LAN.
1) Install the Network Firmware Update Tool to your PC
The option CD-ROM includes the Network Firmware Update Tool, and the Main Unit Firmware Code.
Please refer to the following Operating Instructions to install the Network Firmware Update Tool.
The installation password is "workio".
Operating Instructions:
\xFirmware\Tools\NwFirmup\NwFirmup OI.pdf (Refer to the NW Firmware Update Tool OI on the CD)
Setup:
\xFirmware\Tools\NwFirmup\Setup\Setup.exe
2) Preparing the Firmware Code
Double click the appropriate Destination Shortcut Batch File, and copy the Firmware Code File on the
CD-ROM to the Firmware Data Folder in your PC. Note that the files in the Archive will be extracted
automatically into the designated folder when the Archived file (.exe) is Double-clicked.
Standard Firmware
(SC = Type A)
PCL Firmware
(SC = Type B)
PostScript Firmware
(SC = Type D)
SC
DP-LL80AxVxxxxx_xx DP-LL80BxVxxxxx_xx DP-LL80DxVxxxxx_xx
SPC LL80-SPCAxVxxxxx ←←
Slot 1 FROM PCB Not Required Required Required