(53) Execute Parameter Initialize by following the steps below.
a. Press "FAX/EMAIL" key.
b. Press "FUNCTION" and then "7" keys.
c. Press "MONITOR" four times, then press "∗ (TONE)" to enter the "SERVICE MODE".
d. Press "6" key or "V", "/\" arrow keys to enter "6 RAM INITIALIZE".
e. Press "V", "/\" arrow keys to enter "PARAMETER INITIALIZE".
f. Press "START" key. Wait approximately 10-20 seconds, the unit displays "COMPLETED", then the
unit will return to Service Mode.
g. Turn the Power Switch on the Right side of the machine to the OFF and back to the ON position to
enable the parameter settings.
(54) Verify the position of the stamp on the document. If it is not within the desired location at the bottom
of the document, you can adjust its position by following the steps below.
a. Press "FUNCTION", "ORIGINAL SIZE", and "3" keys sequentially to enter the Service Mode.
b. Press the "6" and "START" keys to enter the F6 Mode (Adjust Parameters).
c. Press "69" to enter "STAMP POSITION ADJ".
d. Press "START" and enter a number (-50 to 50).
Note:
A positive number moves the stamp position closer to the trail edge of the document, conversely,
a negative number moves it in the opposite direction.
To change the current sign to either +/-, press the "RESET" key. (Default setting = 0; 0.3 mm/step)
e. Press "OK" key twice.
f. Press "FUNCTION" and "CLEAR" keys simultaneously to exit the Service Mode.
(55) Proceed the communication test to ensure the Fax Option works properly.