(22) Remove the Process Unit.
Caution:
To prevent damage to the Process Unit, ensure
that the Left Cover is still open before removing
the Process Unit out of the machine.
Caution:
Exercise caution not to scratch the surface of the
OPC Drum (Green), and not to touch it with bare
hands.
Caution:
The OPC Drum is sensitive to light. To prevent
optical exposure problems, do not expose the
OPC Drum to direct sunlight or bright light.
Even if it is a fluorescent lamp, approx.1000 lm/m
2
(1000 lx).
(23) Slide the 1st Paper Tray out of the unit.
(24) Remove 2 Screws.
(25) Remove the Front Cover 1.
(26) Remove 4 Silver Screws.
(27) Remove the Right Cover.
(28) Remove 6 Screws.
(29) Remove the Right Bracket.