Installation manual
24
The AC-IR-3Fq is a triple frequency conventional infrared ame detector produced us-
ing the latest in manufacturing technology. The Detector is using infrared elements suit-
able for the detection of smokeless combustible liquid and gas res, as well as smoke-
forming open re involving carbonaceous materials as contained in wood, plastics, gases,
oil products etc. The Fire evaluation process is done by triple Infrared (3Fq) sensor, pro-
tected by a sapphire glass ltering >6.0μm wavelength radiation. Sensor measures the
hot carbon dioxide in a specic ame wavelength; the B and C sensors simultaneously
measure the interference radiation in near wavelengths. This technique together with
intelligent signal processing through microprocessor and custom algorithms, achieves
excellent detection reliability while maintaining the highest immunity to interference
radiation and sunlight.
5200236-00A
AC-IR-3Fq Trippel-IR Flame detector
The MCP-C is a manual call point for indoor environment and is designed for the
Salwico conventional re alarm systems. Pressing the glass causing it to crack activates
the re alarm. A protective plastic coating on the glass prevents operator injury. The call
point can be tested with a special key included in the delivery.
5200010-01A
MCP-C (GB) Conventional Manual Call Point for wet space IP24
NS-ISOLATOR is a Pepperl-Fuchs Type KFD0-CS-Ex1.51P isolator, which is part of the
Salwico conventional intrinsically safe re detection system. The NS-ISOLATOR barrier
is located in a non-hazardous area (safe area) and forming the interface to IS detectors
and other IS line units. The NS-ISOLATOR does not need a separate power supply. It
is powered directly from the re alarm panel via the loop/section cables, which means
that no extra cables are needed. The NS-ISOLATOR does not need an earth connec-
tion, and thus routine inspection of earth cable and connections is eliminated. The box
has knock-out holes on the sides for the three included cable glands. The glands must
be mounted on the short sides of the box as shown in this data sheet
N1770
NS-ISOLATOR Intrinsically Safe Isolator for Conventional IS Loop Units
with NS-AIN1 Address Unit IP55, Max 10 loop units/isol.
Manual Call Points
Equipment For Hazardous Areas, Zone 0-1
The MCP-C is a manual call point for outdoor environment and is designed for the Sal-
wico conventional re alarm systems. The selected material PC/ABS and the encapsula-
tion, with ingress protection IP67, makes it very suitable for harsh environment. Pressing
the glass causing it to crack activates the re alarm. A protective plastic coating on the
glass prevents operator injury. The call point can be tested with a special key included in
the delivery.
5200014-01A
MCP-C WP (GB) Conventional Manual Call Point for wet space IP67
Salwico Fire Detection System