Installation manual
58
The IM 001 isolated analogue input module accepts analogue voltage or current input.
The module can also drive passive sensors with no additional power supplies. The op-
eration mode of the module can be Voltage, Current or Current Active mode.
Voltage mode - In this operation mode the unit measure the voltage passively. Current
mode - This operation mode measure current with an external power supply.
Current Active mode - In this operation mode the measuring point do not have it’s
own power supply so therefore the active mode will supply the measuring point with
the necessary power.
550080
IM001 for ambient humidity, ambient pressure, engine interface
(rpm / kW and load) 4-20mA
Isolated input module for a Pt100 type temperature sensor.
550070
For systems with more than 1 monitoring point we provide a Multiswitching unit (MSU)
The MSU consists of a PLC and temperature regulators and solenoids for sampling and
purging. The MSU will monitor on each point for 10 minutes.
Consilium probe switching unit (Measuring point 1-10)
Umbilical Sampling Line (USL) consists of 1 power cable, 1 signal cable and 5 PTFE
tubings for sample, purge, dilution and 2 spares. The USL is prepared for connection at
probe side from Consilium for easy connection.
550140
Sample umbilical line per m
TM001 for ambient temperature
Salwico Monitoring System