Installation Sheet

Table Of Contents
CAUTION:
Before installing track head, make sure the hot contact conductor is on the right position.
1. To use track head on one circuit track system, the hot contact conductor at the top of track head must always be in the lower
position. To move the lever from the upper to the lower position, simply push lever do wn.
2. Two circuits track system is designed for use when two separately controlled circuits are needed on one section of track.
Each circuit is rated for 2400 watts and will allow you to control two individual sets of fixtures.
3. To use track head on two circuits track system, the hot contact conductor at the top of track head should be in lower position
for P1 circuit. For P2 circuit, move the lever from the lower to the upper position.
Neutral
Ground tab
Hot contact conductor
Lower position for
one circuit track
system or P1 circuit
of two circuits system
Ground tab
Hot contact conductor
Upper position for
only P2 circuit of
two circuits system
SAVE THESE INSTRUCTIONS
T o circuits trackw
one circuit track
P1
N G
N G
P1
P2
IMPORTANT SAFETY INSTRUCTIONS FOR TRACK LIGHTING
1.Turn off switch at main power source before installing
any track of fittin g.
2.Before installing lampholder, make sure to refer to the
instruction on the backside.
3.Pull down the loching lever and insert "Adaptor contact"
into the slot in the track.
4.Rotate adaptor turn 90 to locked position. NOTE:
Polarity line of lampholder (Grounding tab, polarity side
of two fingers must point to track debossed polarity line
so that the debossed polarity line of the track can be
aligned with the polarity line (side) of adaptor.
5.To remove, depress the locking lever and turn 90
1 4
2
Debossed polarity line
of track
Fiqure(C)
Locking lever
Ground contact
(polarity side of
two fingers)
Fiqure(A )
Adaptor contact
1
Locking lever