Operating Manual

© CalAmp Sentry 4G-900 pico Base Station 50 Wireless (WiMAX) Parameters
2. Update the required parameters in the Pane according to the following descriptions and click
Apply.
Field
Description
Frequency [KHz]
Current / Configured Frequency.
This value will be in use after the next reboot or configuration
flashing.
Values: must be within the range of allowed frequencies (i.e.
between the Min Supported Frequency and Max Supported
Frequency fields see below)
Min / Max Supported
Frequency [KHz]
Min / Max frequency supported by the Base Station (read-only).
Values: Min to Max separated by a comma.
Example: 1350,1450
Tx power [dBm]
Tx Transmit Power Setting. Configured Tx power should be in the
valid range, as determined by the regulations and the device
capabilities (i.e. Min Supported Transmit Power and Max
Supported Transmit Power fields, see below).
Min / Max support
Transmit Power [dBm]
Min / Max supported transmission power by the Base Station
(read-only).
Values: Min and Max separated by a comma.
Example: 10,36
Initial Ranging Power
[dBm]
Maximum Initial Ranging Power. (Look for WiMAX def). If received
power exceeds the maximum Initial ranging power, signal will not
be accepted. Limits signal levels of third party equipment used to
minimize possible interference.
Values: [-90,111]
RF Channel
RF Unit Name or ID.
Values: [0,1]
Active
This Parameter sets\shows the Transmission Activation Status of
the Base Station .
Values:
False - disabled
True - enabled
Tx Power
RF unit Transmit Power (Tx) [dBm].
Values: [-50,100]
Analog RSSI
Analog RSSI level [dBm].
Temperature
RF2 Temperature [Celsius].
Antenna
Antenna Connectivity Status.
Values: [Connected, Disconnected]